BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: A160053
NO PLUMBING INSPECTIONS COMPLETED FOR THIS PROPERTY
Premises: 47-39 5 STREET QUEENS BIN: 4536962     Block: 30   Lot: 22
   

Filed: 5-05 48 AV Census Tract:   7 Health Area:  0720
065661 NONE Admin Area:   A - QUEENS Inspection Area:   C
QUEENS, NY 11101 Community Board:   402
DOB Cross Street(s):    5 STREET,    VERNON BOULEVARD
Status:   K - CLOSED/CANCELLED 06/23/2008
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   07/13/1999 Job Start Date:   07/10/1999
Last Change:   06/23/2008 Job End Date:   07/15/1999
               COMPLETION FEE WAS BILLED
Appointment Status:   
Last Inspection By:   ERROL FLYNN FRANKLIN       On     06/17/2008      
Field Disp:   K - OK TO CANCEL
Energize Recommendation:  
Objection Disposition:  

License #: 011316 Licensee Name: RALPH J RUSSO
Firm: 002733 Firm Name: RJ RUSSO ELECTRIC CO.
Firm Phone: 718-423-4742  Firm Address: 45-57 BELL BLVD BAYSIDE NY 11361 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
Total Fee:  $85.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   K - Store
Store / Other:   BUSINESS
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: GOOD CAUSE MARKETING
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  1  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                       
Total Units : 3 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 1 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 07/13/1999 Notice:  
Power Issued: 07/13/1999 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

*NO PLUMBING INSPECTIONS COMPLETED FOR THIS PROPERTY
INSPECTION FOR APPLICATION #: A160053
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 09/03/1999 09/20/1999 PEN Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 01/07/2000 01/14/2000 PEN Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 01/16/2001 01/22/2001 PEN N (20) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(4) 04/13/2001 05/04/2001 PEN Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(5) 08/22/2001 08/27/2001 TJ1 P (10) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(6) 05/09/2003 05/27/2003 JG1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(7) 11/27/2007 12/03/2007 DAH P (15) (0)
INSPECTION COMMENTS: NONE
 
(8) 06/17/2008 06/23/2008 EFF K (15) (0)
INSPECTION COMMENTS: REMOVED BEFORE FINAL INSPECTION




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Inspection Work Order