BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: B306330
NO PLUMBING INSPECTIONS COMPLETED FOR THIS PROPERTY
Premises: 114 MANHATTAN AVENUE BROOKLYN BIN: 3327961     Block: 3070   Lot: 8
   
Application Completed and Certified

Filed: 114 MANHATTAN AV Census Tract:   505 Health Area:  1500
1-FLOOR Admin Area:   B - BROOKLYN Inspection Area:   B
BROOKLYN, NY 11206 Community Board:   301
Related Job Number:    302019786
DOB Cross Street(s):   MANHATTAN AVENUE,    GRAHAM AVENUE
Status:   C - JOB IS SIGNED OFF 12/03/2008
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  07/09/2008 7:05 AM
Application Entered:   07/09/2008 Job Start Date:   07/10/2008
Last Change:   12/03/2008 Job End Date:   12/30/2008
Appointment Status:   
Last Inspection By:   PETER GREENE       On     11/24/2008      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 012076 Licensee Name: LEONCIO REYES
Firm: 003762 Firm Name: LERCO ELECTRIC LLC
Firm Phone: 718-585-5529  Firm Address: 370 EAST 146TH STREET BRONX NY 10455 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $219.75
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   YES
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: GUADALUPE CHAVEZ
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  1  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  3  1- SET OF 3 # 2 WIRES
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  3  3- 100AMPS 20 CIRCUITS
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total   15  15  36                
Total Units : 69 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 3 #4-Wire 0 #10-Wire 0
Existing Meters 7 + New Meters 3 - Removed Meters 0 = Total Meters 10

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 07/09/2008 Notice: 1 - FIRST NOTICE 09/15/2008
Power Issued: 07/09/2008 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

*NO PLUMBING INSPECTIONS COMPLETED FOR THIS PROPERTY
INSPECTION FOR APPLICATION #: B306330
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 09/08/2008 09/15/2008 MC2 V E (20) (7) Y
INSPECTION COMMENTS: N
 
(2) 11/24/2008 12/03/2008 PGR C R E (40) (0) Y
INSPECTION COMMENTS: N

OBJECTION FOR APPLICATION #: B306330
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 59) AFCI PROTECTION HAS NOT BEEN PROVIDED
APT 1 BEDROOM 210.12B
RSLV 09/08/2008 09/08/2008 11/24/2008
 
002 ( 63) RECEPTACLE OUTLETS NOT IN SUFFICIENT NUMBER
APT 3 KITCHEN COUNTER 210.52
RSLV 09/08/2008 09/08/2008 11/24/2008
 
003 (999) OTHER
APT 3 KITCHEN RECPT OUTLET OVER STOVE NOT PROTECTED FROM PHYSICALDAMAGE 110.2
RSLV 09/08/2008 09/08/2008 11/24/2008
 
004 ( 63) RECEPTACLE OUTLETS NOT IN SUFFICIENT NUMBER
APT 2 KITCHEN COUNTER 210.52
RSLV 09/08/2008 09/08/2008 11/24/2008
 
005 ( 63) RECEPTACLE OUTLETS NOT IN SUFFICIENT NUMBER
1ST FLOOR APT 1,2,3, FEEDER UNDERSIZE 215.2
RSLV 09/08/2008 09/08/2008 11/24/2008
 
006 ( 10) BRANCH CIRCUIT CONDUCTORS ARE NOT PROPER SIZE
1ST FLOOR APT BRANCH CIRCUITS TO ELECT STOVE UNDERSIZE FOR 50A LOAD210.9
RSLV 09/08/2008 09/08/2008 11/24/2008
 
007 ( 6) FEEDER DIAGRAM DID NOT ACCOMPANY APPLICATION FOR INSPECTION
BLDG FEEDER DIAGRAM AND APT LOAD CALCULATION OF SERVICE TO FEED SAMEHAS NOT BEEN PROVIDED TOTAL LOADS 215.5
RSLV 09/08/2008 09/08/2008 11/24/2008



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Inspection Work Order