Electrical Application Details for App #: M359395
NO PLUMBING INSPECTIONS COMPLETED FOR THIS PROPERTY
Premises: 160 7 AVENUE SOUTH MANHATTAN BIN: 1067542     Block: 612   Lot: 7501
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 22 PERRY ST Census Tract:   73 Health Area:  6400
APT.5E,F Admin Area:   M - MANHATTAN Inspection Area:   R
NEW YORK, NY 10014 Community Board:   102
DOB Cross Street(s):   WAVERLY PLACE,    WEST 4 STREET
Status:   C - JOB IS SIGNED OFF 02/09/2016
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  10/05/2014 1:43 PM
Application Entered:   10/05/2014 Job Start Date:   10/06/2014
Last Change:   02/09/2016 Job End Date:   10/01/2015
Appointment Status:   
Last Inspection By:   ELLIS DAVID       On     02/08/2016      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 011313 Licensee Name: ALEX SHTRAMBRAND
Firm: 002687 Firm Name: FAS ELECTRIC, INC.
Firm Phone: 718-714-1212  Firm Address: 2127 NEPTUNE AVE BROOKLYN NY 11224 

Other Licensees and Firms:
License # Licensee Name Firm # Firm Name Type
011285 FINKEL, ANATOLIY 002687 FAS ELECTRIC, INC. RESPONSIBLE REP

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $160.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: POSNER
Owner Business Name: CHARLES RABINOVICH/ARCHIT
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  2  12/24CKTS SINGLE PH MLO
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
005  5E,F  55  31    37  55     
Buildings Total 55  31    37  55            
Total Units : 190 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 01/10/2016
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

*NO PLUMBING INSPECTIONS COMPLETED FOR THIS PROPERTY
INSPECTION FOR APPLICATION #: M359395
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 01/08/2016 01/10/2016 STP V (58) (4)
INSPECTION COMMENTS: NONE
 
(2) 02/08/2016 02/09/2016 EID C R (19) (0)
INSPECTION COMMENTS: FINAL INSPECTION COMPLETED.

OBJECTION FOR APPLICATION #: M359395
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
(FLOOR: 005) NO T.R. OUTLET UNDER SINK 406.11
RSLV 01/08/2016 01/08/2016 02/08/2016
 
002 (999) OTHER
(FLOOR: 006) NO T.R. OUTLET FOR HALLWAY 406.11
RSLV 01/08/2016 01/08/2016 02/08/2016
 
003 (999) OTHER
(FLOOR: 006) NO AFCI PROTECTION FOR CLOSET OUTLET. 210.12
RSLV 01/08/2016 01/08/2016 02/08/2016
 
004 (999) OTHER
(FLOOR: 006) CLOSET LIGHT FIXTURE EXPOSED BULB 2ND FLR. 410.16
RSLV 01/08/2016 01/08/2016 02/08/2016