BIS Menu  |  Plumb. Inspections  |  Electrical Inspection Work Order  |  Electrical Applications  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: Q10524
NO PLUMBING INSPECTIONS COMPLETED FOR THIS PROPERTY
Premises: 86-41 BROADWAY QUEENS BIN: 4045398     Block: 1842   Lot: 9
   

Filed: 86-45 BROADWAY Census Tract:   473 Health Area:  1420
2 THRU 3 FLR Admin Area:   A - QUEENS Inspection Area:   D
QUEENS, NY 11373 Community Board:   404
DOB Cross Street(s):   JUSTICE AVENUE,    GRAND AVENUE
Status:   K - CLOSED/CANCELLED 06/13/2011
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   01/14/1985 Job Start Date:   01/10/1985
Last Change:   06/13/2011 Job End Date:   02/28/1985
Appointment Status:   
Last Inspection By:   THEODORE JUNSCH       On     06/08/2011      
Field Disp:   K - OK TO CANCEL
Energize Recommendation:  
Objection Disposition:  

License #: 012025 Licensee Name: FRANK MERESHENSKY
Firm: 001941 Firm Name: P & M ELECT'L CONTR. CORP
Firm Phone: 718-627-1483  Firm Address: 1618 MERMAID AVENUE, SUITE 1 BROOKLYN NY 11224 

Historical Licensees and Firms:
License # Licensee Name Firm # Firm Name  
011135 POTCHIN, MOSHE 001941 P & M ELECT'L CONTR. CORP

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
Total Fee:  $27.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   A - One Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: YU YUAN LIN
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: Notice:  
Power Issued: 06/12/1985 Response:  

Follow-Up: K - (CLOSED)
Wires Comments: 103 OUTLETS/27 FIXT./2 5 JAW METER EQUIP
Contractor's Comments:  E 500

 
Inspection Details
 

*NO PLUMBING INSPECTIONS COMPLETED FOR THIS PROPERTY
INSPECTION FOR APPLICATION #: Q10524
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 12/26/1985 LD1 N (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 06/24/1986 07/19/1986 LD1 N (15) (0)
INSPECTION COMMENTS: NO ACCESS LEFT CARD FOR OWNER
 
(3) 10/03/1986 10/16/1986 LD1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(4) 10/17/1986 10/27/1986 LD1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(5) 11/28/1986 12/04/1986 DH2 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(6) 05/02/1987 05/06/1987 LD1 N (20) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(7) 06/08/2011 06/13/2011 TJ1 K (15) (0) Y
INSPECTION COMMENTS: BLDG DEMOLISHED NEW CONSTRUCTION