BIS Menu  |  Electrical Inspection Work Order  |  Property Permits  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: A068166
NO PLUMBING INSPECTIONS COMPLETED FOR THIS PROPERTY
Premises: 31-30 14 STREET QUEENS BIN: 4005762     Block: 518   Lot: 43
   
Application Completed and Certified

Filed: 31-30 14 ST Census Tract:   77 Health Area:  0300
GRD FL Admin Area:   A - QUEENS Inspection Area:   A
QUEENS, NY 11106 Community Board:   401
DOB Cross Street(s):    31 ROAD,    31 DRIVE
Status:   C - JOB IS SIGNED OFF 10/12/1993
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   06/25/1991 Job Start Date:   06/28/1991
Last Change:   10/12/1993 Job End Date:   08/23/1991
Appointment Status:   
Last Inspection By:   PRIVATE AGENCY       On     09/30/1993      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  G - NO COMMENT
Objection Disposition:  

License #: 010693 Licensee Name: STEVEN M DUFFY
Firm: 002021 Firm Name: ISTRA ELECTRIC CORP.
Firm Phone: 718-932-9135  Firm Address: 12-24 30TH AVENUE L.I.C. NY 11102 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $111.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   A - One Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: D&S PLUMG HEATING CORD
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  2  
B. 101 Up to 200 AMPS  1  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  2  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  2  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 30  36    18  30              
Total Units : 118 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 2 #4-Wire 1 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 08/05/1991 Notice:  
Power Issued: 08/05/1991 Response:  

Follow-Up: K - (CLOSED)
Wires Comments: EXCAT NUMBR UNITS PART II YES UNDETERMIND
Contractor's Comments:  

 
Inspection Details
 

*NO PLUMBING INSPECTIONS COMPLETED FOR THIS PROPERTY
INSPECTION FOR APPLICATION #: A068166
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 08/16/1991 09/11/1991 RJM Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 09/13/1991 10/07/1991 RJM Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 10/11/1991 10/28/1991 RJM Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(4) 11/13/1991 11/25/1991 RJM J G (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(5) 04/09/1993 04/28/1993 RJM Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(6) 05/13/1993 05/18/1993 RJM N (25) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(7) 07/30/1993 08/04/1993 JBF Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(8) 09/30/1993 10/12/1993 X01 C G (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Inspection Work Order  |  Property Permits  |  Back