BIS Menu  |  Elevators  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: Y094523
NO PLUMBING INSPECTIONS COMPLETED FOR THIS PROPERTY
Premises: 400 EAST 155 STREET BRONX BIN: 2095348     Block: 2376   Lot: 40
   

Filed: 698 MELROSE AV Census Tract:   67 Health Area:  3900
980185 CELLAR Admin Area:   Y - BRONX Inspection Area:   B
BRONX, NY 10455 Community Board:   201
DOB Cross Street(s):   EAST 154 STREET,    EAST 155 STREET
Status:   K - CLOSED/CANCELLED 09/29/1999
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   07/07/1999 Job Start Date:   07/05/1999
Last Change:   09/29/1999 Job End Date:   07/15/1999
               COMPLETION FEE WAS BILLED
Appointment Status:   
Last Inspection By:   ROGALEWSKI, M       On     09/23/1999      
Field Disp:   K - OK TO CANCEL
Energize Recommendation:  
Objection Disposition:  

License #: 011416 Licensee Name: MIKHAIL KOLKER
Firm: 001818 Firm Name: OLYMPIC ELECT WIRING CORP
Firm Phone: 718-768-2262  Firm Address: 133 50TH STREET BROOKLYN NY 11232 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
9 - OTHER
Total Fee:  $34.00
Other Work:   ELEC'L WRK FOR 3MTRS#Y091599;THIS FOR 1MTR
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: MELROSE ESTATES HOUSING
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  1  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  1  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

Access:   CONTRACTOR Contact Phone:   718-768-2262

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 4 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 07/07/1999 Notice:  
Power Issued: 07/07/1999 Response:  

Follow-Up: K - (CLOSED)
Wires Comments: RAMON VELEZ,JR., PRES = 718-993-3504
Contractor's Comments:  BEC#071362; MELROSE COURT

 
Inspection Details
 

*NO PLUMBING INSPECTIONS COMPLETED FOR THIS PROPERTY
INSPECTION FOR APPLICATION #: Y094523
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 09/23/1999 09/29/1999 MIR K (1) (0)
INSPECTION COMMENTS: SEE APPL Y095320




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Elevators  |  Electrical Inspection Work Order  |  Back