BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: A280539
NO PLUMBING INSPECTIONS COMPLETED FOR THIS PROPERTY
Premises: 30-92 CRESCENT STREET QUEENS BIN: 4539419     Block: 570   Lot: 55
   
Application Completed and Certified

Filed: 30-94 CRESCENT ST Census Tract:   73 Health Area:  0300
ENTIRE BUILDING Admin Area:   A - QUEENS Inspection Area:   A
QUEENS, NY 11102 Community Board:   401
Related Job Number:    410114353
DOB Cross Street(s):    30 DRIVE,    31 AVENUE
Status:   C - JOB IS SIGNED OFF 06/18/2010
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  09/11/2009 2:09 PM
Application Entered:   09/11/2009 Job Start Date:   09/14/2009
Last Change:   06/18/2010 Job End Date:   07/14/2010
Appointment Status:   
Last Inspection By:   BOTSCH, E       On     06/04/2010      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  

License #: 011452 Licensee Name: GARY C GELORUM
Firm: 002905 Firm Name: G. G. ELECTRIC CORP.
Firm Phone: 718-518-2923  Firm Address: 202 NORMAN AVENUE BROOKLYN NY 11222 

Work Started or Filed by Others: NO
Work Category:   N - NEW BUILDING Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
8 - BOILER/BURNER WIRING
Total Fee:  $1,665.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   YES
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   Z - Other
Store / Other:   33 UNIT BUILDING
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: ROBERT CERRONE
Owner Business Name: 41 DR. REALTY CORP.
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  1  
B. 101 Up to 200 AMPS  2  
C. 201 Up to 600 AMPS  1  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  33  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  2  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  33  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
BAS    10                   
GND    10                   
LOB    10                   
002  2A  20             
002  2B  20             
002  2C  20             
002  2D  20             
002  2E  20             
003  3A  20             
003  3B  20             
003  3C  20             
003  3D  20             
003  3E  20             
003  3F  20             
004  4A  20             
004  4B  20             
004  4C  20             
004  4D  20             
004  4E  20             
004  4F  20             
005  5A  20             
005  5B  20             
005  5C  20             
005  5D  20             
005  5E  20             
005  5F  20             
006  6A  20             
006  6B  20             
006  6C  20             
006  6D  20             
006  6E  20             
006  6F  20             
007  7A  20             
007  7B  20             
007  7C  20             
007  7D  20             
Buildings Total 195  664  66  170  165                
Total Units : 1260 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 33 #4-Wire 0 #10-Wire 1
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 09/11/2009 Notice:  
Power Issued: 09/11/2009 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

*NO PLUMBING INSPECTIONS COMPLETED FOR THIS PROPERTY
INSPECTION FOR APPLICATION #: A280539
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 06/04/2010 06/10/2010 EBT C E (60) (0) Y
INSPECTION COMMENTS: CERTIFICATE




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Inspection Work Order