BIS Menu  |  Applications  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: B354672
NO PLUMBING INSPECTIONS COMPLETED FOR THIS PROPERTY
Premises: 313 GRAFTON STREET BROOKLYN BIN: 3081977     Block: 3581   Lot: 16
   
Application Completed and Certified

Filed: 313 GRAFTON ST Census Tract:   894 Health Area:  5820
LIVONIA AVENUE /1ST & 2ND FLRS Admin Area:   B - BROOKLYN Inspection Area:   H
BROOKLYN, NY 11212 Community Board:   316
Special Place Name:   MILLER RESIDENCE
DOB Cross Street(s):   LIVONIA AVENUE,    EAST 98 STREET
Status:   C - JOB IS SIGNED OFF 03/24/2014
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  10/03/2012 9:03 AM
Application Entered:   10/03/2012 Job Start Date:   10/03/2012
Last Change:   03/24/2014 Job End Date:   10/28/2012
Appointment Status:   
Last Inspection By:   CAMPBELL, C       On     03/13/2014      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 009094 Licensee Name: J. ROBERT MANN, JR.
Firm: 000455 Firm Name: E-J ELEC. INSTALLATION CO
Firm Phone: 718-786-9400  Firm Address: 46-41 VERNON BLVD. LONG ISLAND CITY NY 11101 

Work Started or Filed by Others: YES
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $67.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   B - Two Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: DORCAS MILLER
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
BAS    10  15                 
001    10  25    10               
002    10  25    10               
Buildings Total 30  65    25                  
Total Units : 120 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 03/24/2014 Notice: 1 - FIRST NOTICE 12/16/2013
Power Issued: 03/24/2014 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  JOB# AD/12-0100 REPLACING PERMIT #B311408 FILED BY ANOTHERCONTRACTOR

 
Inspection Details
 

*NO PLUMBING INSPECTIONS COMPLETED FOR THIS PROPERTY
INSPECTION FOR APPLICATION #: B354672
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 04/26/2013 04/30/2013 DEX J (50) (0) Y
INSPECTION COMMENTS: N
 
(2) 11/19/2013 12/03/2013 JSB N (15) (0) Y
INSPECTION COMMENTS: N
 
(3) 12/10/2013 12/16/2013 CJH A (65) (10) Y
INSPECTION COMMENTS: N
 
(4) 03/13/2014 03/24/2014 CLC C R E (15) (0) Y
INSPECTION COMMENTS: N

OBJECTION FOR APPLICATION #: B354672
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
CELLAR FLOORS PNL CIR NOT GROUPED 210.4D
RSLV 12/10/2013 12/10/2013 03/13/2014
 
002 (999) OTHER
CELLAR PNLS CIR NOT SIMUTANEOUSLY DISCONNECTED 210.4B
RSLV 12/10/2013 12/10/2013 03/13/2014
 
003 ( 34) KNOCKOUTS ARE NOT CLOSED IN PANEL BOX
CELLAR SUB PNL KO MISSING 110.12A
RSLV 12/10/2013 12/10/2013 03/13/2014
 
004 ( 22) FIXED EQUIPMENT IS NOT PROPERLY GROUNDED
CELLAR SUB PNL GRN CONDUCTOR 250.112
RSLV 12/10/2013 12/10/2013 03/13/2014
 
005 (999) OTHER
ALL FLS THROUGHOUT GFCI RECEPTICLE OUTLETS NOT TR 406.11
RSLV 12/10/2013 12/10/2013 03/13/2014
 
006 (999) OTHER
1ST FL BATHROOM BRANCH CIR NOT PROVIDED 210.52 (C3)
RSLV 12/10/2013 12/10/2013 03/13/2014
 
007 (999) OTHER
1ST FL BATHROOM KITCHEN COUNTER RECEPTICLES SAME CIR 210.52 (B2)
RSLV 12/10/2013 12/10/2013 03/13/2014
 
008 ( 29) OUTLET BOXES ARE NOT COVERED
1ST FL REAR BEDROOM RIGHT SIDE 314.25
RSLV 12/10/2013 12/10/2013 03/13/2014
 
009 ( 35) APPROVED OUTLETS HAVE NOT BEEN PROVIDED FOR AIR CONDITIONERS
1ST FL LIVING ROOM AMEND 210.52 (1)
RSLV 12/10/2013 12/10/2013 03/13/2014
 
010 (999) OTHER
1ST FL AFCI PROTECTION NOT PROVIDED THROUGHOUT 210.12B
RSLV 12/10/2013 12/10/2013 03/13/2014



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.