Electrical Application Details for App #: Y159390
NO PLUMBING INSPECTIONS OPEN FOR THIS PROPERTY
Premises: 2995 3 AVENUE BRONX BIN: 2001399     Block: 2376   Lot: 54
   
Application Completed and Certified

Filed: 2995 THIRD AV Census Tract:   67
STREET Admin Area:   Y - BRONX Inspection Area:   B
BRONX, NY 10455 Community Board:   201
DOB Cross Street(s):   EAST 154 STREET,    EAST 155 STREET
Status:   C - JOB IS SIGNED OFF 01/11/2013
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  03/25/2012 11:46 AM
Application Entered:   03/25/2012 Job Start Date:   03/26/2012
Last Change:   01/11/2013 Job End Date:   12/31/2012
Appointment Status:   
Last Inspection By:   SCHIAVO, JAMES       On     12/27/2012      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 011227 Licensee Name: KURT EBINGER
Firm: 002629 Firm Name: KURT EBINGER ELEC CONST
Firm Phone: 718-885-0824  Firm Address: 107 CAROLL STREET INC D/B/A KEE ELECTRIC BRONX NY 10464 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
Total Fee:  $445.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   Z - Commercial/Residential (2  Stores, 3 Apartments)
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: JON KIM
Owner Business Name: ASA EQUITIESLLC
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  4  4 100AMPW/60AMPCB
B. 101 Up to 200 AMPS  2  2 200 AMP
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  3  3 SETS OF #6 THHN
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  2  2 SET 3/0
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  4  100 16 CIR ML
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  2  2 200 AMP 42 CIR ML
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
001  12               
003  12               
004  12               
Buildings Total 24  36  18                  
Total Units : 84 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 4 #4-Wire 2 #10-Wire 0
Existing Meters 1 + New Meters 0 - Removed Meters 0 = Total Meters 1

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 03/25/2012 Notice: 1 - FIRST NOTICE 12/20/2012
Power Issued: 03/25/2012 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  RENOVATION TO THE 3 APARTMENTS & 2 STORES. NEW ELECTRICAL WIRING

 
Inspection Details
 

*NO PLUMBING INSPECTIONS OPEN FOR THIS PROPERTY
INSPECTION FOR APPLICATION #: Y159390
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 12/11/2012 12/20/2012 EBA A E (60) (4) Y
INSPECTION COMMENTS: VIOL
 
(2) 12/27/2012 01/11/2013 JSV C R E (50) (0) Y
INSPECTION COMMENTS: CERT

OBJECTION FOR APPLICATION #: Y159390
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
BSMT/ COLLECTOR BAR REQ 250.94
RSLV 12/11/2012 12/11/2012 12/27/2012
 
002 (999) OTHER
ALL PANEL/ MULTIWIRE CIRCUITS MUST BE SIMONTANIOUSLY DISCONNECTEC210.4.B
RSLV 12/11/2012 12/11/2012 12/27/2012
 
003 (999) OTHER
ALL PANEL/ GROUNDED & UNGROUNDED CONDUCTORS MUST BE GROUPDED 210.4.D
RSLV 12/11/2012 12/11/2012 12/27/2012
 
004 ( 59) AFCI PROTECTION HAS NOT BEEN PROVIDED
ALL/ COMBINATION TYPE AFCI REQUIRED
RSLV 12/11/2012 12/11/2012 12/27/2012



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Applications  |  Print Electrical Permit  |  Electrical Inspection Work Order  |  Back