BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: B105033
NO PLUMBING INSPECTIONS COMPLETED FOR THIS PROPERTY
Premises: 406 FLATBUSH AVENUE EXTENSION BROOKLYN BIN: 3000354     Block: 149   Lot: 17
   
Application Completed and Certified

Filed: 583 FULTON ST Census Tract:   33 Health Area:  1200
J0135 1FL BSMT Admin Area:   B - BROOKLYN Inspection Area:   D
BROOKLYN, NY 11201 Community Board:   302
DOB Cross Street(s):   HANOVER PLACE,    FLATBUSH AVENUE EXTENSION
Status:   C - JOB IS SIGNED OFF 03/05/1993
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   10/15/1992 Job Start Date:   10/09/1992
Last Change:   12/18/1992 Job End Date:   10/09/1992
Appointment Status:   
Last Inspection By:   ROSE, M.       On     12/14/1992      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  G - NO COMMENT
Objection Disposition:  

License #: 010590 Licensee Name: DEMETRIOS VOUYIOUKLIS
Firm: 000755 Firm Name: JIM ELECTRIC CORP.
Firm Phone: 718-833-2389  Firm Address: 223 52ND STREET BROOKLYN NY 11220 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
9 - OTHER
Total Fee:  $10.00
Other Work:   REPAIR WIRIG REPLACE 2 BALLST
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   K - Store
Store / Other:   JEWLRY
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: M.C O'BRIEN
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                 
Total Units : 10 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Wires Comments: 1-LINE FOR GAS BLOWR HEATR
Contractor's Comments:  

 
Inspection Details
 

*NO PLUMBING INSPECTIONS COMPLETED FOR THIS PROPERTY
INSPECTION FOR APPLICATION #: B105033
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 12/14/1992 12/18/1992 MX1 C G (30) (0)
INSPECTION COMMENTS: /




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Inspection Work Order