BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: Z153965
NO PLUMBING INSPECTIONS COMPLETED FOR THIS PROPERTY
Premises: 115 CENTRAL PARK WEST MANHATTAN BIN: 1028618     Block: 1124   Lot: 27
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 115 CENTRAL PARK W Census Tract:   157 Health Area:  4000
23RD FLOOR Admin Area:   Z - UPPER MANHATTAN Inspection Area:   E
NEW YORK, NY 10023 Community Board:   107
DOB Cross Street(s):   WEST 71 STREET,    CENTRAL PARK EXIT WEST 72 ST
Status:   C - JOB IS SIGNED OFF 03/28/2017
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  03/07/2016 3:56 PM
Application Entered:   03/07/2016 Job Start Date:   03/08/2016
Last Change:   03/28/2017 Job End Date:   03/07/2017
Appointment Status:   
Last Inspection By:   URIM SYLA       On     10/27/2016      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  

License #: 011171 Licensee Name: TREVOR DUNWELL
Firm: 002607 Firm Name: APPROVED ELECTRIC CORP.
Firm Phone: 718-882-3145  Firm Address: 3550 WHITE PLAINS ROAD STE #9 BRONX NY 10467 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $163.75
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: DANNY MURPHY
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  1  200 AMPS
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  3/0
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  2  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
023      35    20  30             
Buildings Total   35    20  30                
Total Units : 85 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 1 #10-Wire 0
Existing Meters 100 + New Meters 1 - Removed Meters 1 = Total Meters 100

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 03/07/2016 Notice:  
Power Issued: 03/07/2016 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  REPLACING SUB METER FROM 100 AMP TO 200 AMPS.

 
Inspection Details
 

*NO PLUMBING INSPECTIONS COMPLETED FOR THIS PROPERTY
INSPECTION FOR APPLICATION #: Z153965
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 10/27/2016 10/28/2016 UMS C (30) (0) Y
INSPECTION COMMENTS: NO SERVICE WORK DONE