BIS Menu  |  Application Data   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
LAA Application Details
Premises: 25-59 37 STREET QUEENS
BIN: 4010156    Block: 653    Lot: 13 LAA #: 440510724
Documents Collected  |   Plumbing Insp   |   Payment History   |   Virtual Job Folder

Printable (PDF) version of Permit

DOB NOW: Inspections

Last Action: SIGNED-OFF BY DGH - 12/13/2019 (I)
Pre-Filed: 09/20/2018 Approved: 09/20/2018 3:07 PM Expiration: 09/20/2019
  Electronically Filed: Yes
Work Description
  Location Information (Filed At)
House No(s): 25-59 Street Name: 37TH STREET
Borough: QUEENS Block: 653 Lot: 13 BIN: 4010156 CB No: 401
Work on Floor(s): CEL
  Fee Assessment
Fee Structure: STANDARD
Estimated Cost: Category 2 - Estimated Cost of Unlimited Work  $8,000.00
  Additional Information
Building Characteristics: 1, 2, or 3 Family
Administrative Notes: 11/28/18 PAA DISAPP -ADDITIONAL METERS FOR 1 AND 2 FAMILY.DWELLINGS
IS REQUIRE APPROVAL FOR AUTHORIZED BOROUGH PERSONAL. 12/31/18 PAA DISAPP - ADDITIONAL METERS FOR 1 AND 2 FAMILYROVAL FOR AUTHORIZED BOROUGH PERSONAL. 01/25/19 PAA DISAPP - PROVIDE ELECTRICAL PERMIT FOR ELECTRICAL COOKING.SEE CHECKLIST(CORRECTED). 02/06/19 PAA APPROVED  
Audit Results: ACCEPTED on  02/06/2019
  Applicant Information
Name: MARVIN WASOFF
Business Name: WASOFF PLBG & UTILITY CO Business Phone: 718-387-1400
Business Address: 36-05C COLLEGE POINT BLVD, FLUSHING, NY 11354 Business Fax: 516-739-2748
License Type: MASTER PLUMBER
License Number: 000868
Applicant Insured By: FALLS LAKE NATIONAL INS Insurance Expires: 10/28/2018
  Work Detail
  Plumbing: Category 2 GAS PLUMBING WORK   Gas Authorization Required
  Proposed Work Summary:
OIL TO GAS CONVERSION.INSTALL APPROX 65' OF 1 1/4" GAS PIPE IN CELLAR.INSTALL ONE WILLIAMSON BOILER AND CONNECT THE UNIT TO EXISTING GOOD CONDITION AND ADEQUATELY SIZED CHIMNEY.REGISTER EXISTING HOT WATER HEATER AND EXISTING DRYER IN CELLAR.SINCE THE 2ND FLOOR USES EXISTING ELECTRIC COOKING STOVE,ONLY THE BOILER, H.W.H., AND DRYER IN CELLAR ARE CONNECTED TO THE EXISTING 2ND FLOOR GAS METER.THE 1ST FL USES AN EXISTING GAS COOKING RANGE THAT IS ALREADY CONNECTED TO A SEPARATE.SEE ATTACHED DRYER SKETCH. A1019/8TG,A1022/8TG,A1101/8SX,A1114/8XS,A1220/8XS,A0115/9XS,A0129/9DD  

Additional Gas Information
Meters:  2  CELL EXISTING
Risers:  2  CEL,001
Gas Uses:   Heat    Cooking    Water Heater     Dryer   
  Appliance Data
Total Number
of Appliance(s)
Floor Location
of Appliance
Item-Manufacturer
Name
Listing Agency
Name and ID #
Model Number
Input (BTUs/hr)
1 CEL WILLIAMSON BOILER CSA 1502-81/MEA 414-00-E GSA-175 175000
1 CEL AO SMITH CSA 2901-85 FCG-75 400 75000
1 CEL WHIRLPOOL DRYER CSA 2722-81 WGD70HEBW 22000
1 001 FRIGIDAIRE STOVE CSA 2711-81 FFGF3047LSH 38000
  Asbestos Abatement Compliance
The scope of work does not require related asbestos abatement as defined in the regulations of the NYC DEP.
ACP5 DEP Control #  466931  CAI #  150639


If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.

BIS Menu  |  Application Data