BIS Menu  |  Property Browse  |  Application Data  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
LAA Application Details
Premises: 7302 3 AVENUE BROOKLYN
BIN: 3147817    Block: 5917    Lot: 38 LAA #: 320637833
Documents Collected  |   Plumbing Insp   |   Payment History   |   Virtual Job Folder

Last Action: DISAPPROVED - 04/02/2015 (J)
Pre-Filed: 08/18/2014 Approved:    
  Electronically Filed: No
Work Description
  Location Information (Filed At)
House No(s): 7302 Street Name: THIRD AVENUE
Borough: BROOKLYN Block: 5917 Lot: 38 BIN: 3147817 CB No: 310
Work on Floor(s): CEL
  Fee Assessment
Fee Structure: STANDARD
Estimated Cost:  $8,000.00
  Additional Information
Building Characteristics: Other
Legalization: No
Reviewer Comments: 033015 BFP CIVIL PENALTY FEE WAIVED DUE TO BONA FIDE PURCHASER CEL OK
Administrative Notes: 10/23/14-LAA DISAP- SUPERSEDED JOB#REQ'D. SEE CKLST. 10/23/14-L2 DIAP ADD'L L2 FORM REQ'D FOR PEND WORK W/OUT PERMIT STOP WORK ORDER VIOL(S).030215-L2 DISAP-IN SECTION#6 MISSING SIGNATURE FROM NOTARY/OWNER OR OWNER DESIGNEE. SEE CKLST.030615-DISAP-SUPERSEDED JOB# REQ'D. L2 DISAP-IN SEC#6 MISSING SIGNATURE FROM NOTARY/OWNER OR OWNER DESIGNEE.031915-DISAP-INCORRECT JOB #  
  Applicant Information
Name: IRA AUSLANDER
Business Name: ARCO PLBG AND HTG INC Business Phone: 718-336-0507
Business Address: 15 OCEAN AVENUE, BROOKLYN, NY 11225
License Type: MASTER PLUMBER
License Number: 001020
Applicant Insured By: NORTHFIELD INSURANCE COMP Insurance Expires: 01/26/2016
  Work Detail
  Plumbing: GAS PLUMBING WORK   Gas Authorization not Required
  Proposed Work Summary:
ACTIVATE GAS PORTION OF EXISTING BURNER MFG: POWERFLAME; MDL #CR1-GO-12; MEA#97-78-E VOL.III; FILED BY OIL BURNER INSTALL LIC. #4257B. CONNECT TO EXISTING 1-1/2" BLACK PIPE; INSTALL NEW GAS METER BAR AND NEW GAS METER. TEST GAS LINE. VENTED THROUGH EXIST CHIMNEY.
*0815BQ/1216BQ*  

Additional Gas Information
Meters:  1  CEL
Risers:  1  CEL
Gas Uses:   Heat    Other: TANKLESS COIL
  Appliance Data
Total Number
of Appliance(s)
Floor Location
of Appliance
Item-Manufacturer
Name
Listing Agency
Name and ID #
Model Number
Input (BTUs/hr)
1 CEL POWER FLAME CSA#112250 CR1-GO-12 931000
2 CEL AO SMITH CSA#1466914 XCV-50 40000
  Asbestos Abatement Compliance
The scope of work does not require related asbestos abatement as defined in the regulations of the NYC DEP.


If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.

BIS Menu  |  Property Browse  |  Application Data  |  Back