BIS Menu  |  Application Data   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
LAA Application Details
Premises: 131 SOUTH 2 STREET BROOKLYN
BIN: 3062943    Block: 2405    Lot: 32 LAA #: 321345692
Documents Collected  |   Plumbing Insp   |   Payment History   |   Virtual Job Folder

Last Action: DISAPPROVED - 01/02/2018 (J)
Pre-Filed: 11/13/2017 Approved:    
  Electronically Filed: No
Work Description
  Location Information (Filed At)
House No(s): 131 Street Name: SOUTH 2 STREET
Borough: BROOKLYN Block: 2405 Lot: 32 BIN: 3062943 CB No: 301
Work on Floor(s): BAS
  Fee Assessment
Fee Structure: STANDARD
Estimated Cost: Category 2 - Estimated Cost of Unlimited Work  $9,372.00
  Additional Information
Building Characteristics: Other
Legalization: No
Administrative Notes: 01/02/18 DISAPPROVED - DEP CONTROL NUMBER AND CERTIFIED ASBESTOS INVESTIGATOR NUMBER REQUIRED. SEE CHECKLIST  
  Applicant Information
Name: VINCENT TAVELLA
Business Name: TAVELLA PLBG & HTG CORP Business Phone: 718-843-2542
Business Address: 101-11 100 STREET, OZONE PARK, NY 11416
License Type: MASTER PLUMBER
License Number: 000545
Applicant Insured By: HARLEYSVILLE WORCESTER Insurance Expires: 08/18/2018
  Work Detail
  Plumbing: Category 2 GAS PLUMBING WORK   Gas Authorization Required
  Proposed Work Summary:
SUPERSEDING LAA #350794887 THAT SUPERSEDING LAA #310270890 THAT HAS EXPIRED BY LIMITATIONS. REGISTERING THE EXISTING BOILER AND HOT WATER HEATER THAT WERE PREVIOUSLY INSTALLED UNDER LAA #310270890. REPLACE BOILER WITH ONE BURNHAM IN-9. REPLACE WATER HEATER WITH ONE AO SMITH 75 GALLON HOT WATE HEATER. EQUIPMENT VENTS THROUGH EXISTING CHIMNEY THAT IS IN GOOD CONDITION. ENCLOSED L2 FORM AND PROOF THAT ACP5 FORM WAS FILED WITH DOB.

_______________________________________________________________1109/7CM*  

Additional Gas Information
Meters:  1  BASEMENT
Risers:  1  BASEMENT
Gas Uses:   Heat    Water Heater    
  Appliance Data
Total Number
of Appliance(s)
Floor Location
of Appliance
Item-Manufacturer
Name
Listing Agency
Name and ID #
Model Number
Input (BTUs/hr)
1 BAS BURNHAM ETL/INTERTEK #ANSI-Z21.13 IN-9 280000
1 BAS AO SMITH CSA CLASS #2902-13 PCG-75 75000
  Asbestos Abatement Compliance
The scope of work is exempt from the asbestos requirement as defined in the regulations promulgated by the NYC DEP (15 RCNY 1-23(b)) or is an alteration to a building constructed pursuant to plans submitted for approval on or after April 1,1987, in accordance with §28-106.1.


If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.