BIS Menu  |  Plumb. Insp. History  |  LAA Permit Data  |  Application Data  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
LAA Application Details
Premises: 161 BEDFORD AVENUE BROOKLYN
BIN: 3061801    Block: 2312    Lot: 3 LAA #: 320806749
Documents Collected  |   Plumbing Insp   |   Payment History   |   Virtual Job Folder

Last Action: DISAPPROVED - 10/18/2016 (J)
Pre-Filed: 10/06/2016 Approved:    
  Electronically Filed: No
Work Description
  Location Information (Filed At)
House No(s): 161 Street Name: BEDFORD AVENUE
Borough: BROOKLYN Block: 2312 Lot: 3 BIN: 3061801 CB No: 301
Work on Floor(s): CEL,BAS,001,002,003
  Fee Assessment
Fee Structure: STANDARD
Estimated Cost: Category 2 - Estimated Cost of Unlimited Work  $6,500.00
  Additional Information
Building Characteristics: 1, 2, or 3 Family
Legalization: No
Administrative Notes: 10/18/16 DISAPPROVED LISTING AGENCY NAME AND NUMBER INVALID.
PLEASE CHECKLIST  
  Applicant Information
Name: HENRY E SAMUELS
Business Name: CITYWIDE PLUMBING NYC COR Business Phone: 718-886-1993
Business Address: 31-70 COLLEGE POINT BOULEVARD, FLUSHING, NY 11354
License Type: MASTER PLUMBER
License Number: 002294
Applicant Insured By: ARCH SPECIALTY INS COMPAN Insurance Expires: 02/01/2017
  Work Detail
  Plumbing: Category 2 GAS PLUMBING WORK   Gas Authorization Required
  Proposed Work Summary:
FILE PERMIT TO TEST GAS LINE TO RESTORE GAS SERVICE DUE TO GAS LEAKS,REMOVE UNION ON HOUSE PIPE.REPAIR APPROX.1FT X1'' 60 FTX3/4'' GAS PIPE CONNECTS TO EX COOK IN 001,002,003 FLOOR CONNECTED TO THE EXISTING.EX BOILER AND HWH VENTS THRU EXISTING CHIMNEY IN CELLAR.GAS PIPING CONNECTED TO EXISTING.GAS BOILER IS LINED,CLEANED AND IN GOOD WORKING CONDITION.NO HOLES OF FIRE STOPS WILL COMPROMISED.GAS PIPINGS IN PUBLIC AREA.GAS USAGE HWH,COOK,HEAT.WORK WILL BE DONE IN CELLAR.REGISTER EX BOILER ,HWH.
103/6PB  

Additional Gas Information
Meters:  3  EX CEL
Risers:  3  EX CEL -003
Gas Uses:   Heat    Cooking    Water Heater    
  Appliance Data
Total Number
of Appliance(s)
Floor Location
of Appliance
Item-Manufacturer
Name
Listing Agency
Name and ID #
Model Number
Input (BTUs/hr)
1 CEL AO SMITH CSA#112710 XCB50 37000
1 CEL AMERICAN STANDARD 999 G-105 105000
  Asbestos Abatement Compliance
The scope of work does not require related asbestos abatement as defined in the regulations of the NYC DEP.
ACP5 DEP Control #  3264945  CAI #  116635


If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.

BIS Menu  |  Plumb. Insp. History  |  LAA Permit Data  |  Application Data  |  Back