BIS Menu  |  Application Data   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
LAA Application Details
Premises: 768 48 STREET BROOKLYN
BIN: 3012764    Block: 777    Lot: 32 LAA #: 340385461
Documents Collected  |   Plumbing Insp   |   Payment History   |   Virtual Job Folder

Printable (PDF) version of Permit

DOB NOW: Inspections

Last Action: SIGNED-OFF BY CAY - 01/20/2017 (I)
Pre-Filed: 05/24/2016 Approved: 05/24/2016 4:33 PM Expiration: 05/24/2017
  Electronically Filed: Yes
Work Description
  Location Information (Filed At)
House No(s): 768 Street Name: 48 STREET
Borough: BROOKLYN Block: 777 Lot: 32 BIN: 3012764 CB No: 307
Work on Floor(s): CEL
  Fee Assessment
Fee Structure: STANDARD
Estimated Cost: Category 2 - Estimated Cost of Unlimited Work  $6,000.00
  Additional Information
Building Characteristics: 1, 2, or 3 Family
Administrative Notes: 06/07/16 PAA APPROVED  
Audit Results: ACCEPTED on  06/07/2016
  Applicant Information
Name: HENRY W TRAKTMAN
Business Name: METROPOLITAN HEAT & POWER Business Phone: 718-941-7600
Business Address: 820 CONEY ISLAND AVE, BROOKLYN, NY 11218
License Type: MASTER PLUMBER
License Number: 001341
Applicant Insured By: HARKEYSVILLE WIRCESTER IN Insurance Expires: 09/08/2016
  Work Detail
  Plumbing: Category 2 GAS PLUMBING WORK   Gas Authorization Required
  Proposed Work Summary:
REPLACE OIL BOILER WITH GAS BOILER & HWH CONNECTED TO EXISTING TERRACOTTA LINED AND IN GOOD CONDITION CHIMNEY IN CELLAR AND CONNECTED TO APPROX 50'OF 1"-1/2" GAS PIPING.RECONNECT EXISTING 1ST FL COOKING LINE (APPROX 15' 3/4" ) TO EXISTING GAS METER AND TEST THE SAME. ONE BURNHAM MODEL#205NI-G2,INPUT 130MBH OUTPUT 108MBH.ONE AO SMITH HWH MODEL# XCV50 40,000 BTU/HR.FIRE STOPS FOR OUR WORK WILL BE RESTORED TO COMPLY WITH NYC CODE.NO GAS PIPE IN PUBLIC HALLWAYS.INSTALL NEW GAS METER BAR AND REMOUNT EXISTING METER TO NEW METER BAR 0602/6HT  

Additional Gas Information
Meters:  1  CELLAR EXISTING
Risers:  1  CELLAR- 1ST FLOOR
Gas Uses:   Heat    Cooking    Water Heater    
  Appliance Data
Total Number
of Appliance(s)
Floor Location
of Appliance
Item-Manufacturer
Name
Listing Agency
Name and ID #
Model Number
Input (BTUs/hr)
1 CEL BURNHAM INTERTEK/ETL#ANSI-Z21.13 205NI-G2 130000
1 CEL A O SMITH CSA #2901-85 XCV50 40000
  Asbestos Abatement Compliance
The scope of work does not require related asbestos abatement as defined in the regulations of the NYC DEP.
ACP5 DEP Control #  3243820  CAI #  115876


If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.

BIS Menu  |  Application Data