Premises: 713 HENRY STREET BROOKLYN
BIN: 3008457    Block: 536    Lot: 6 LAA #: 321341785
Documents Collected  |   Plumbing Insp   |   Payment History   |   Virtual Job Folder

Last Action: DISAPPROVED - 10/12/2017 (J)
Pre-Filed: 10/06/2017 Approved:    
  Electronically Filed: No
Work Description
  Location Information (Filed At)
House No(s): 713 Street Name: HENRY STREET
Borough: BROOKLYN Block: 536 Lot: 6 BIN: 3008457 CB No: 306
Work on Floor(s): CEL
  Fee Assessment
Fee Structure: STANDARD
Estimated Cost: Category 2 - Estimated Cost of Unlimited Work  $9,500.00
  Additional Information
Building Characteristics: Other
Legalization: No
Administrative Notes: 10/12/17 DISAP-CHECK OFF ONLY THE TYPES OF GAS USAGE THAT APPLIES TO THIS FILING; SEE CHECKLIST.  
  Applicant Information
Name: PASQUALE QUARATINO
Business Name: HARRIS PLUMBING & HEATING Business Phone: 718-495-3400
Business Address: 184 GLENMORE AVENUE, BROOKLYN, NY 11212
License Type: MASTER PLUMBER
License Number: 001370
Applicant Insured By: NATIONWIDE INSURANCE CO Insurance Expires: 04/03/2018
  Work Detail
  Plumbing: Category 2 GAS PLUMBING WORK   Gas Authorization Required
  Proposed Work Summary:
TEST/REP/REPL 1"2"OR 3"GAS PIPE ST. SIDE OF GAS MTRS. 1 TWIN SET FOR THE COOKING AND 1 MTR FOR THE MOD.BOILERS HTG HW&DRYERS. GAS SERV WON'T BE TURNED OFF. UTILITY WILL COMPRESS GAS TO STOVES FOR REPAIR OF OVERHEAD.2"-3"2"-2"5'- 1" HOW. GAS PIP. ON HOUSE SIDE OF MET TO BOIL AND DRYERS WILL BE TEST/REP/REPL TOTAL AMT OF THAT MIGHT BE REPL TO BOIL, DRYER 40'-2. 40"-11/4",30'-3/4". NO PIP IN PUBL HALLS. FIRE STOPS TO BE REST. 31 STOVES. 1 FL TO 4FT 1085000BTU INP.
1004/7GM  

Additional Gas Information
Meters:  3  CELL (EXISTING, 1 IS TWIN SET)
Risers:  2  CELL-004(EXISTING)
Gas Uses:   Heat    Other: TANKESS COILS
  Appliance Data
Total Number
of Appliance(s)
Floor Location
of Appliance
Item-Manufacturer
Name
Listing Agency
Name and ID #
Model Number
Input (BTUs/hr)
1 BAS SLANT FIN CSA12042223 GGT-1200E 120000
2 BAS WHRILPOOL CSA7.1A2007 CGM2743BQ0 44000
  Asbestos Abatement Compliance
The scope of work is exempt from the asbestos requirement as defined in the regulations promulgated by the NYC DEP (15 RCNY 1-23(b)) or is an alteration to a building constructed pursuant to plans submitted for approval on or after April 1,1987, in accordance with §28-106.1.