Last Action: SIGNED-OFF BY MBW - 08/07/2018 (I)
Pre-Filed: 06/18/2018 Approved: 06/21/2018 5:39 PM Expiration: 06/21/2019
  Electronically Filed: No
Work Description
  Location Information (Filed At)
House No(s): 1575 Street Name: THIERIOT AVENUE
Borough: BRONX Block: 3925 Lot: 18 BIN: 2112832 CB No: 209
Work on Floor(s): CEL 001 thru 006
  Fee Assessment
Fee Structure: STANDARD
Estimated Cost: Category 2 - Estimated Cost of Unlimited Work  $5,000.00
  Additional Information
Building Characteristics: Other
Legalization: No
Administrative Notes: 07/23/18-PAA APPROVED  
  Applicant Information
Name: MICHAEL H BALOGLOU
Business Name: ABSOLUTE PLBG HTG & MECH Business Phone: 718-951-2131
Business Address: 989 EAST 35TH STREET, BROOKLYN, NY 11210
License Type: MASTER PLUMBER
License Number: 001923
Applicant Insured By: HARLEYSVILLE WORCESTER Insurance Expires: 12/01/2018
  Work Detail
  Plumbing: Category 2 GAS PLUMBING WORK   Gas Authorization Required
  Proposed Work Summary:
EWN16504-DUE TO GAS CO. SHUT DOWN GAS FOR (60)METERS, 59-APTS:(1A-6A,1B-6B,1C- 6C,1D-6D,1E-6E,1F-6F,1H-6H,1J-5J,1K-6K)AND 1 LAUNDRY RM. IN CEL:DIRECT REPLACE MENT OF 48 GAS MTRS BARS &INSTALL (8) 1-1/4"LOCKABLE ISOLTION VALVES. DIRECT REPLACEMENT GAS PIPING:APPX:CEL-3"X40',2"X40', 1-1/4X240',1"X100',3/4"X210', 1ST FL-3/4"X30', 2ND FL-3/4'X30',3RD FL-3/4'X10',4TH FL-3/4"X10'.DIRECT REPLAC EMENT OF (10) 3/4" STOVE GAS APPLIANCE VALVES PER FLR. 1ST,2ND,3RD,4TH,5TH,6TH FL-ONLY (9) 3/4" VALVES. FIRESTOPS NOT COMPROMISED. NO PIPING IN PUBLIC HALL WAY. 0615/8YZ__A0719/8VA  

Additional Gas Information
Meters:  60  CELLAR (EXISTING)
Risers:  60  CELLAR, 001-006
Gas Uses:   Cooking    Dryer   
  Asbestos Abatement Compliance
The scope of work is exempt from the asbestos requirement as defined in the regulations promulgated by the NYC DEP (15 RCNY 1-23(b)) or is an alteration to a building constructed pursuant to plans submitted for approval on or after April 1,1987, in accordance with §28-106.1.