LAA Application Details
Premises: 1966 ARTHUR AVENUE BRONX
BIN: 2011976    Block: 3068    Lot: 55 LAA #: 220281460
Documents Collected  |   Plumbing Insp   |   Payment History   |   Virtual Job Folder

Printable (PDF) version of Permit

DOB NOW: Inspections

Last Action: SIGNED-OFF BY DPR - 07/27/2017 (I)
Pre-Filed: 03/08/2017 Approved: 06/08/2017 9:08 AM Expiration: 06/08/2018
  Electronically Filed: No
Work Description
  Location Information (Filed At)
House No(s): 600 Street Name: EAST 178 STREET
Borough: BRONX Block: 3068 Lot: 55 BIN: 2011976 CB No: 206
Work on Floor(s): BAS
  Fee Assessment
Fee Structure: STANDARD
Estimated Cost: Category 2 - Estimated Cost of Unlimited Work  $5,000.00
  Additional Information
Building Characteristics: Other
Legalization: Yes
Administrative Notes: 03/28/17 PAA DISAPPROVED - ALTERATION TO GAS PIPING REQUIRES A GAS TEST FOR APPLIANCES ON THE GIVEN METER. SEE CHECKLIST
042717 DISAPP- INSTALLATION OF FIXTURES OR COOKING APPLIANCES FOR BASEMENT OR CELLAR MUST BE ACCOMPANIED BY A CERTIFIED C OF O; SEE CHECKLIST 6/8/17-CORRECTED  
  Applicant Information
Name: ROBERTO VELAZQUEZ
Business Name: BARGAIN PLMBING & HTGING Business Phone: 718-585-5758
Business Address: 1060 WASHINGTON AVENUE, BRONX, NY 10456
License Type: MASTER PLUMBER
License Number: 001212
Applicant Insured By: PREFERRED CONTRACTORS Insurance Expires: 10/10/2017
  Work Detail
  Plumbing: Category 2 GAS PLUMBING WORK   Gas Authorization not Required
  Proposed Work Summary:
TO CLEAR THE VIO #35222514Z, CAP & REMOVE SEC: FGC 480.2. DRIPS FUTURE CONNECTS EXIST DOWN STREAM OF APPLIANCE OBSERVED ON 12/13/16 FUTURE GAS CONNECTION IN BSMT. REMOVING APPROX. 19FT OF 1" 1/2" GAS PIPE AND INSTALL_APRX 39FT OF 3" NO HUB PIPE TO CORRECT VIOLATION#3525515K BARGAIN IS GOING_TO REPLACE ALL PVC PIPE WITH CAST IRON & NO HUB COUPLINGS APPROX. 28FT OF 1" 1/4" PIPE. TO CORRECT VIO 35222516M, BARGAIN_IS GOING TO REMOVE ALL STORAGE AROUND THE GAS METER LOCATED IN THE BAS. GAS INTEGRITY TEST WILL BE PERFORMED. FIRE STOP WILL NOT BE COMPROMISED. SUPERSEDING#240172139. 406/7DS0512/7DS*  

Additional Gas Information
Meters:  1  BASEMENT
Risers:  1  BASEMENT
Gas Uses:   Cooking    Boiler Pilot   
  Asbestos Abatement Compliance
The scope of work is exempt from the asbestos requirement as defined in the regulations promulgated by the NYC DEP (15 RCNY 1-23(b)) or is an alteration to a building constructed pursuant to plans submitted for approval on or after April 1,1987, in accordance with §28-106.1.