BIS Menu  |  Insp. Results  |  Application Data  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
LAA Application Details
Premises: 582 SOUTHERN BOULEVARD BRONX
BIN: 2004126    Block: 2603    Lot: 20 LAA #: 240127260
Documents Collected  |   Plumbing Insp   |   Payment History   |   Virtual Job Folder

Printable (PDF) version of Permit

DOB NOW: Inspections

Last Action: SIGNED-OFF BY DPR - 07/20/2016 (I)
Pre-Filed: 12/18/2015 Approved: 12/18/2015 3:02 PM Expiration: 12/18/2016
  Electronically Filed: Yes
Work Description
  Location Information (Filed At)
House No(s): 582 Street Name: SOUTHERN BLVD
Borough: BRONX Block: 2603 Lot: 20 BIN: 2004126 CB No: 202
Work on Floor(s): BAS 001 thru 005
  Fee Assessment
Fee Structure: STANDARD
Estimated Cost: Category 2 - Estimated Cost of Unlimited Work  $4,000.00
  Additional Information
Building Characteristics: Other
Administrative Notes: 4/25/16 DISAPPROVED CHECK/MONEY ORDER REQUIRED FOR BALANCE DUE$54.40. PLEASE SEE CHECKLIST
05/18/16-PAA DISAPPROVED-CHECK OFF ONLY THE TYPES OF GAS USAGE THAT APPLY TO THIS FILING. SEE CHECKLIST.
05/19/16-PAA APPROVED  
  Applicant Information
Name: THOMAS CATALANO
Business Name: CATALANO PLBG & HTG INC Business Phone: 718-931-8200
Business Address: 2419 EAST TREMONT AVENUE, BRONX, NY 10461 Business Fax: 718-239-9735
License Type: MASTER PLUMBER
License Number: 001795
Applicant Insured By: HARLEYSVILLE INSURANCE Insurance Expires: 10/10/2016
  Work Detail
  Plumbing: Category 2 GAS PLUMBING WORK   Gas Authorization Required
  Proposed Work Summary:
TO INSTALL FOUR (4) 2" LOCK WING GAS COCKS TO ISOLATE RISERS ON METER BANK LOCATED IN BASEMENT FOR FUTURE GAS REPAIRS AS PER CON ED REQUEST-WILL USE APPRX 10' OF 2" BLK PIPE & FOUR 2" LOCK WING GAS VALVES-WILL TEST ALL 35 APTS- NO GAS IN PUBLIC HALLWAYS-FIRESTOPS AS PER NYC CODE-APPLIANCES ON EXISTING 35 METERS ARE STOVES. ADDITIONAL LAA TO FOLLOW IF NECESSARY. A414/6GM/A0426/6GM_0519/6GM  

Additional Gas Information
Meters:  35  BASEMENT
Risers:  35  BASEMENT THROUGH 5TH FLOORS
Gas Uses:   Cooking   
  Appliance Data
Total Number
of Appliance(s)
Floor Location
of Appliance
Item-Manufacturer
Name
Listing Agency
Name and ID #
Model Number
Input (BTUs/hr)
7 1 STOVE MAYTAG MGR7685AW 245000
7 2 STOVE MAYTAG MGR7685AW 245000
7 3 STOVE MAYTAG MGR7685AW 245000
7 4 STOVE MAYTAG MGR7685AW 245000
7 5 STOVE MAYTAG MGR7685AW 245000
  Asbestos Abatement Compliance
The scope of work is exempt from the asbestos requirement as defined in the regulations promulgated by the NYC DEP (15 RCNY 1-23(b)) or is an alteration to a building constructed pursuant to plans submitted for approval on or after April 1,1987, in accordance with §28-106.1.


If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.

BIS Menu  |  Insp. Results  |  Application Data  |  Back