BIS Menu  |  Insp. Results  |  Application Data  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
LAA Application Details
Premises: 156 MANHATTAN AVENUE MANHATTAN
BIN: 1085312    Block: 1843    Lot: 20 LAA #: 122315789
Documents Collected  |   Plumbing Insp   |   Payment History   |   Virtual Job Folder

Printable (PDF) version of Permit

DOB NOW: Inspections

Last Action: APPROVED - 07/12/2016 (E)
Pre-Filed: 06/27/2016 Approved: 07/12/2016 9:49 AM Expiration: 07/12/2017
  Electronically Filed: No
Work Description
  Location Information (Filed At)
House No(s): 156 Street Name: MANHATTAN AVENUE
Borough: MANHATTAN Block: 1843 Lot: 20 BIN: 1085312 CB No: 107
Work on Floor(s): CEL
  Fee Assessment
Fee Structure: STANDARD
Estimated Cost: Category 2 - Estimated Cost of Unlimited Work  $4,000.00
  Additional Information
Building Characteristics: Other
Legalization: No
  Applicant Information
Name: CARL TERMINE JR
Business Name: ADVANCED P,MECH & SPR COR Business Phone: 718-788-3600
Business Address: 123 50TH STREET, BROOKLYN, NY 11232
License Type: MASTER PLUMBER
License Number: 001338
Applicant Insured By: HARLEYSVILLE INS CO.NY Insurance Expires: 03/06/2017
  Work Detail
  Plumbing: Category 2 GAS PLUMBING WORK   Gas Authorization Required
  Proposed Work Summary:
IN CELLAR, REGISTER(4)MAYTAG GAS DRYERS (EACH DRYER HAS 2 POCKET DRYERS)VENTED THROUGH DRYER EXHAUST SYSTEM.REMOVE(8)GAS FLEX CONNECTORS AND REPLACE WITH APPROX 24' OF 3/4"GAS PIPING.(APPROX 6' PER UNIT)ALL WORK DONE AFTER GAS SHUT OFF VALVE.LAUNDRY ROOM SHOWN ON CO#85937.NOTE:FIRESTOPS WILL NOT BE COMPROMISED.FILING TO REGISTER REPLACEMENT DRYERS.

0623/6IS  

Additional Gas Information
Meters:  1  CELLAR
Risers:  1  CELLAR
Gas Uses:   Dryer   
  Appliance Data
Total Number
of Appliance(s)
Floor Location
of Appliance
Item-Manufacturer
Name
Listing Agency
Name and ID #
Model Number
Input (BTUs/hr)
4 CEL MAYTAG CSA#2723-81 MLG26 24000
  Asbestos Abatement Compliance
The scope of work is exempt from the asbestos requirement as defined in the regulations promulgated by the NYC DEP (15 RCNY 1-23(b)) or is an alteration to a building constructed pursuant to plans submitted for approval on or after April 1,1987, in accordance with §28-106.1.