BIS Menu  |  Bldg Info Search  |  Application Data  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
LAA Application Details
Premises: 200 WEST 26 STREET MANHATTAN
BIN: 1082532    Block: 775    Lot: 44 LAA #: 122325554
Documents Collected  |   Plumbing Insp   |   Payment History   |   Virtual Job Folder


DOB NOW: Inspections

Last Action: APPROVED - 11/13/2018 (E)
Job Closed on:  04/13/2022 CLOSED BY TGI WORK REFILED & SIGNED OFF UNDER M00336657-LA
Pre-Filed: 05/02/2017 Approved: 11/13/2018 10:33 AM Expiration: 11/13/2019
  Electronically Filed: No
Work Description
  Location Information (Filed At)
House No(s): 200 Street Name: WEST 26 STREET
Borough: MANHATTAN Block: 775 Lot: 44 BIN: 1082532 CB No: 104
Work on Floor(s): 002
  Fee Assessment
Fee Structure: STANDARD
Estimated Cost: Category 2 - Estimated Cost of Unlimited Work  $6,500.00
  Additional Information
Building Characteristics: Other
Legalization: No
Administrative Notes: 05/26/17-DISAPPROVED-MUST TEST ALL APPLIANCES CONNECTED TO THIS METER. 5/30/17- MAILED OUT._11/13/18 CORRECTED AND APPROVED..  
  Applicant Information
Name: CARL TERMINE JR
Business Name: ADVANCED P,MECH & SPR COR Business Phone: 718-788-3600
Business Address: 123 50TH STREET, BROOKLYN, NY 11232
License Type: MASTER PLUMBER
License Number: 001338
Applicant Insured By: STATE NATIONAL INSUR CO Insurance Expires: 03/06/2019
  Work Detail
  Plumbing: Category 2 GAS PLUMBING WORK   Gas Authorization Required
  Proposed Work Summary:
FILED IN RESPONSE TO OBJECTION. NOTE ALL WORK IS DONE FROM APPLIANCE VALVE TO APPLIANCE ONLY. ON THE 2ND FLOOR, REPLACE EXISTING DRYERS FILED UNDER JOB# 102004073 WITH(6)MAYTAG DRYERS. DIRECT REPLACEMENT OF APPROX 60'OF 3/4"GAS PIPING FROM EXISTING GAS DRYER VALVE. FIRESTOPS WILL NOT BE COMPROMISED. DRYERS VENTED THROUGH DRYER EXHAUST SYSTEM NOTE:EXISTING DRYERS& SPRIKLER SYSTEM INSTALLED& SIGNED OFF UNDER JOB#102004073, LAUNDRY ROOM SHOWN UNDER
C OF O#1020004073. ________________________________________________0501/7MAIL__0828/8LK_1101/8LK  

Additional Gas Information
Meters:  1  CELLAR
Risers:  1  CELLAR-002
Gas Uses:   Dryer   
  Appliance Data
Total Number
of Appliance(s)
Floor Location
of Appliance
Item-Manufacturer
Name
Listing Agency
Name and ID #
Model Number
Input (BTUs/hr)
6 002 MAYTAG CSA#2723-81 MLG26 80000
  Asbestos Abatement Compliance
The scope of work is exempt from the asbestos requirement as defined in the regulations promulgated by the NYC DEP (15 RCNY 1-23(b)) or is an alteration to a building constructed pursuant to plans submitted for approval on or after April 1,1987, in accordance with §28-106.1.


If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.

BIS Menu  |  Bldg Info Search  |  Application Data  |  Back