LAA Application Details
Premises: 53 WEST 105 STREET MANHATTAN
BIN: 1055600    Block: 1841    Lot: 11 LAA #: 140602417
Documents Collected  |   Plumbing Insp   |   Payment History   |   Virtual Job Folder


DOB NOW: Inspections

Last Action: APPROVED - 02/03/2017 (E)
Job Closed on:  12/27/2018 CLOSED BY KRM WORK SUPERSEDED BY LAA#123245826 & SIGNED-OFF
Pre-Filed: 02/03/2017 Approved: 02/03/2017 2:33 PM Expiration: 02/03/2018
  Electronically Filed: Yes
Work Description
  Location Information (Filed At)
House No(s): 53 Street Name: W 105 STREET
Borough: MANHATTAN Block: 1841 Lot: 11 BIN: 1055600 CB No: 107
Work on Floor(s): CEL
  Fee Assessment
Fee Structure: STANDARD
Estimated Cost: Category 2 - Estimated Cost of Unlimited Work  $5,000.00
  Additional Information
Building Characteristics: Other
Administrative Notes: 033117- PAA APPROVED. 6/26/17 (PAA CORRECTED & APPROVED)
1/26/18 DISAP- WITHDRAWAL REQUEST, MUST OBTAIN PL SIGNOFF, SEE CHECKLIST. R031518-DISAPPROVED-THE FOLLOWING DOES NOT MATCH THE ORIGINAL LAA FILING SCOPE OF WORK. SEE CHECKLIST FOR FURTHER REJECTIONS. R033018-THE FOLLOWING DOES NOT MATCH THE ORIGINAL LAA FILING SCOPE OF WORK.  
Audit Results: ACCEPTED on  04/03/2017
  Applicant Information
Name: LOP K MOY
Business Name: FULL CIRCLE PLUMBING CORP Business Phone: 212-226-2313
Business Address: 79 BRIDGE STREET,LOWER LEVEL, BROOKLYN, NY 11201 Business Fax: 212-941-0547
License Type: MASTER PLUMBER
License Number: 002241
Applicant Insured By: ATLANTIC CASUALTY Insurance Expires: 04/11/2017
  Work Detail
  Plumbing: Category 2 GAS PLUMBING WORK   Gas Authorization Required
  Proposed Work Summary:
REPLACE APPROXIMATELY 25 L.F.OF EXISTING EXPOSED 3/4 GAS PIPING IN CELLAR FOR EACH RISER. RISERS FOR FLOORS 1, 2, 3, 4, 5. TOTAL RISERS IS 5. TOTAL OF 125 L.F. OF 3/4" GAS PIPING. ALL PIPING EXPOSED. USE EXISTING ANCHORS AND HANGERS. NO FIRESTOPPING WORK REQUIRED. NO ACP5 REQUIRED. ALL EXISTING VERTICAL PIPING AND STOVES TO REMAIN. PERFORM LOW PRESSURE GAS TEST. LABEL ALL NEW PIPING, CALL FOR DOB INSPECTIONS AS REQUIRED. EXSTG STOVES LOCATED IN UNITS 2,4,6,8 AND 10. NO PIPING IN PUBLIC HALLWAYS. ALL PIPING IN CELLAR.
A0227/7LM, 0321/7LM, A0410/7JF/JF/LM__R0312/8LM__R0330/8JF  

Additional Gas Information
Meters:  5  CELLAR
Risers:  5  1,2,3,4,5
Gas Uses:   Cooking   
  Asbestos Abatement Compliance
The scope of work is exempt from the asbestos requirement as defined in the regulations promulgated by the NYC DEP (15 RCNY 1-23(b)) or is an alteration to a building constructed pursuant to plans submitted for approval on or after April 1,1987, in accordance with §28-106.1.


If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.