BIS Menu  |  Application Data   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
LAA Application Details
Premises: 1 UNIVERSITY PLACE MANHATTAN
BIN: 1008832    Block: 548    Lot: 1 LAA #: 122303337
Documents Collected  |   Plumbing Insp   |   Payment History   |   Virtual Job Folder

Printable (PDF) version of Permit

DOB NOW: Inspections

Last Action: APPROVED - 12/22/2015 (E)
Pre-Filed: 12/11/2015 Approved: 12/22/2015 6:59 PM Expiration: 12/22/2016
  Electronically Filed: No
Work Description
  Location Information (Filed At)
House No(s): 1 Street Name: UNIVERSITY PLACE
Borough: MANHATTAN Block: 548 Lot: 1 BIN: 1008832 CB No: 102
Work on Floor(s): CEL
  Fee Assessment
Fee Structure: STANDARD
Estimated Cost: Category 2 - Estimated Cost of Unlimited Work  $6,000.00
  Additional Information
Building Characteristics: Other
Legalization: No
  Applicant Information
Name: CARL TERMINE JR
Business Name: ADVANCED P,MECH & SPR COR Business Phone: 718-788-3600
Business Address: 123 50TH STREET, BROOKLYN, NY 11232
License Type: MASTER PLUMBER
License Number: 001338
Applicant Insured By: HARLEYSVILLE INS CO.NY Insurance Expires: 03/06/2016
  Work Detail
  Plumbing: Category 2 GAS PLUMBING WORK   Gas Authorization Required
  Proposed Work Summary:
IN CELLAR, REGISTER (6)MAYTAG GAS DRYERS. (EACH DRYER HAS 2 DRYER POCKETS.) VENTED THROUGH DRYER EXHAUST SYSTEM. REMOVE (12) GAS FLEX CONNECTORS AND REPLACE WITH APPROX.36' OF 3/4" GAS PIPING.(APPROX.6' PER UNIT.) ALL WORK.DONE AFTER GAS SHUT OFF VALVE. LAUNDRY ROOM IS SHOWN ON C OF O #45236. NOTE:FIRESTOP WILL NOT BE COMPROMISED. FILING TO REGISTER REPLACEMENT DRYERS.

1210/5IS  

Additional Gas Information
Meters:  1  CELLAR
Risers:  1  CELLAR
Gas Uses:   Dryer   
  Appliance Data
Total Number
of Appliance(s)
Floor Location
of Appliance
Item-Manufacturer
Name
Listing Agency
Name and ID #
Model Number
Input (BTUs/hr)
6 CEL MAYTAG ANSI#Z223.1/NFPA54 MLG26 24000
  Asbestos Abatement Compliance
The scope of work is exempt from the asbestos requirement as defined in the regulations promulgated by the NYC DEP (15 RCNY 1-23(b)) or is an alteration to a building constructed pursuant to plans submitted for approval on or after April 1,1987, in accordance with §28-106.1.


If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.

BIS Menu  |  Application Data