BIS Menu  |  Schedule A   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Schedule 'A'
Premises: 555 WEST 22 STREET MANHATTAN Job No: 121204366
BIN: 1012322    Block: 694    Lot: 7502 Doc No: 01 Job Type: NB - NEW BUILDING
Comments
EXISTING /
PROPOSED
FLOORS
FRM - TO
NO.
PERS
LIVE
LOAD
2022/2014/2008
Code?
OCC
GRP
UNITS
 
ZONE
USE
EXISTING CEL -
PROPOSED CEL - 1 OG Y S-2 2
PARKING (29 SPACES) ACCESSORY TO RESIDENTIAL, BICYCLE STORAGE (26 SPACES) (DRY FLOOD PROOF) (DISPLAY -1P)

EXISTING CEL -
PROPOSED CEL - 74 OG Y R-2 2B
POOL ACCESSORY TO RESIDENTIAL,POOL DECK,HOT TUB,ICE PLUNGE,MEN'S POOL LOCKER ROOM INCLUDING SAUNA AND STEAM ROOM, WOMEN'S POOL LOCKER ROOM INCLUDING SAUNA AND STEAM ROOM, POOL LOBBY (DRY FLOOD PROOF)(DISPLAY CL)

EXISTING CEL -
PROPOSED CEL - 7 OG Y S-2 2
TENANT STORAGE,BUILDING STORAGE ROOMS,COMPACTOR ROOM 1,COMPACTOR ROOM 2(DRY FLOOD PROOF) (DISPLAY CL)

EXISTING CEL -
PROPOSED CEL - 10 OG Y R-2 2
STAFF WOMEN'S LOCKER ROOM,STAFF MEN'S LOCKER ROOM,SUPER'S OFFICE, MAINTENANCE ROOM(DRY FLOOD PROOF) (DISPLAY CL)

EXISTING CEL -
PROPOSED CEL - 30 OG Y R-2 2B
S-2
LEISURE POOL ACCESSORY TO RESIDENTIAL,LEISURE POOL DECK,POOL STORAGE,POOL EQUIPMENT ROOM(DRY FLOOD PROOF) (DISPLAY CL)

EXISTING CEL -
PROPOSED CEL - 4 OG Y B 4
COMMUNITY FACILITY(DRY FLOOD PROOF) (DISPLAY CL)

EXISTING CEL -
PROPOSED CEL - 5 OG Y F-2 2
SEWER POE ROOM,ELECTRIC POE ROOM,WATER DENTION TANK ROOM,FUEL OIL TANK ROOM,GAS METER ROOM,MECHANICAL ROOM(DRY FLOOD PROOF) (DISPLAY CL)

EXISTING CEL -
PROPOSED CEL - 27 OG Y R-2 2B
DOG GROOMING AREA, LAUNDRY, SPORTS COURT, GOLF SIMULATOR ACCESSORY TO RESIDENTIAL (DRY FLOOD PROOF) (DISPLAY CL)

EXISTING 001 - 001
PROPOSED 001 - 001 71 40 Y R-2 2B
EVENT LOUNGE ACCESSORY TO RESIDENTIAL(DRY FLOOD PROOF) (DISPLAY LOBBY)

EXISTING 001 - 001
PROPOSED 001 - 001 61 40 Y R-2 2B
RESIDENTIAL AMENITY SPACE INCLUDING CARDIO CENTER,YOGA ROOM,INSTRUCTION ROOM(DRY FLOOD PROOF) (DISPLAY LOBBY)

EXISTING 001 - 001
PROPOSED 001 - 001 13 100 Y F-2 2
GENERATOR ROOM,FIRETANK ROOM,ELECTRICAL ROOMS, MECHNICAL ROOMS (DRY FLOOD PROOF) (DISPLAY LOBBY)

EXISTING 001 - 001
PROPOSED 001 - 001 23 40 Y R-2 2
S-2
RESIDENTIAL LOBBY,CONCIERGE,ELEVATOR LOBBY,MAIL ROOM,FLOOD BARRIER STORAGE ROOM(DRY FLOOD PROOF)(DISPLAY LOBBY)

EXISTING 001 - 001
PROPOSED 001 - 001 100 Y S-2 2
PARKING ENTRANCE, MOTORCOURT

EXISTING 001 - 001
PROPOSED 001 - 001 56 40 Y R-2 2B
RESIDENTIAL AMENITY SPACE INCLUDING TODDLER ROOM,FAMILY ROOM,CHILDREN'S PLAY ROOM,MUSIC ROOM,SCREENING ROOM(DRY FLOOD PROOF) (DISPLAY LOBBY)

EXISTING 001 - 001
PROPOSED 001 - 001 3 40 Y S-2 2
BICYCLE STORAGE ROOM (46 SPACES) (DRY FLOOD PROOF) (DISPLAY LOBBY)

EXISTING 001 - 001
PROPOSED 001 - 001 3 40 Y B 4
COMMUNITY FACILITY LOBBY(DRY FLOOD PROOF) (DISPLAY LOBBY)

EXISTING 002 - 002
PROPOSED 002 - 002 40 Y R-2 4 2
4 CLASS A APARTMENTS(EAST TOWER, DISPLAY 3)

EXISTING 002 - 002
PROPOSED 002 - 002 40 Y F-2 2
MECHANICAL ROOM(WEST TOWER, DISPLAY 3)

EXISTING 002 - 002
PROPOSED 002 - 002 40 Y R-2 5 2
5 CLASS A APARTMENTS (WEST TOWER, DISPLAY 3)

EXISTING 002 - 002
PROPOSED 002 - 002 7 40 Y R-2 2B
TODDLER ROOM MEZZANINE RESIDENTIAL AMENITY SPACE(WEST TOWER, DISPLAY 3)

EXISTING 003 - 004
PROPOSED 003 - 004 40 Y R-2 8 2
8 CLASS A APARTMENTS PER FLOOR (WEST TOWER, DISPLAY 4-5)

EXISTING 003 - 004
PROPOSED 003 - 004 40 Y R-2 4 2
4 CLASS A APARTMENTSPER FLOOR (EAST TOWER, DISPLAY 4-5)

EXISTING 003 - 003
PROPOSED 003 - 003 40 Y R-2 1 2
2 LOWER LEVELS OF CLASS A APARTMENTS (EAST TOWER, DISPLAY 4)

EXISTING 004 - 004
PROPOSED 004 - 004 40 Y R-2 1 2
2 UPPER LEVELS OF CLASS A APARTMENTS (EAST TOWER, DISPLAY 5)

EXISTING 005 - 005
PROPOSED 005 - 005 40 Y R-2 4 2
4 CLASS A APARTMENTS (EAST TOWER, DISPLAY 6)

EXISTING 005 - 005
PROPOSED 005 - 005 40 Y R-2 8 2
8 CLASS A APARTMENTS (WEST TOWER, DISPLAY 6)

EXISTING 005 - 005
PROPOSED 005 - 005 40 Y R-2 1 2
2 LOWER LEVELS OF CLASS A APARTMENTS (EAST TOWER, DISPLAY 6)

EXISTING 006 - 006
PROPOSED 006 - 006 40 Y R-2 6 2
6 CLASS A APARTMENTS PER FLOOR (WEST TOWER, DISPLAY 7)

EXISTING 006 - 006
PROPOSED 006 - 006 40 Y R-2 1 2
2 UPPER LEVELS OF CLASS A APARTMENTS (EAST TOWER, DISPLAY 7)

EXISTING 006 - 006
PROPOSED 006 - 006 40 Y R-2 4 2
4 CLASS A APARTMENTS PER FLOOR (EAST TOWER, DISPLAY 7)

EXISTING 007 - 007
PROPOSED 007 - 007 40 Y R-2 1 2
2 LOWER LEVELS OF CLASS A APARTMENTS (EAST TOWER, DISPLAY 8)

EXISTING 007 - 008
PROPOSED 007 - 008 40 Y R-2 4 2
4 CLASS A APARTMENTS PER FLOOR (EAST TOWER, DISPLAY 8-9)

EXISTING 007 - 007
PROPOSED 007 - 007 40 Y R-2 6 2
6 CLASS A APARTMENTS (WEST TOWER, DISPLAY 8)

EXISTING 008 - 008
PROPOSED 008 - 008 40 Y R-2 1 2
2 UPPER LEVELS OF CLASS A APARTMENTS (EAST TOWER, DISPLAY 9)

EXISTING 008 - 008
PROPOSED 008 - 008 40 Y R-2 5 2
5 CLASS A APARTMENTS (WEST TOWER, DISPLAY 9)

EXISTING 009 - 009
PROPOSED 009 - 009 40 Y R-2 1 2
2 LOWER LEVELS OF CLASS A APARTMENTS (EAST TOWER, DISPLAY 10)

EXISTING 009 - 009
PROPOSED 009 - 009 40 Y R-2 4 2
4 CLASS A APARTMENTS (EAST TOWER, DISPLAY 10)

EXISTING 009 - 009
PROPOSED 009 - 009 40 Y R-2 6 2
6 CLASS A APARTMENTS (WEST TOWER, DISPLAY 10)

EXISTING 010 - 010
PROPOSED 010 - 010 40 Y R-2 4 2
4 CLASS A APARTMENTS(EAST TOWER, DISPLAY 11)

EXISTING 010 - 010
PROPOSED 010 - 010 40 Y R-2 2 2
2 CLASS A APARTMENTS(WEST TOWER, DISPLAY 11)

EXISTING 010 - 010
PROPOSED 010 - 010 40 Y R-2 1 2
2 UPPER LEVELS OF CLASS A APARTMENTS (EAST TOWER, DISPLAY 11)

EXISTING 011 - 011
PROPOSED 011 - 011 40 Y R-2 1.5 2
3 LOWER LEVELS OF CLASS A APARTMENTS (EAST TOWER, DISPLAY 12)

EXISTING 011 - 012
PROPOSED 011 - 012 40 Y R-2 2 2
2 CLASS A APARTMENTS PER FLOOR (EAST TOWER, DISPLAY 12-14)

EXISTING 011 - 012
PROPOSED 011 - 012 40 Y R-2 3 2
3 CLASS A APARTMENTS PER FLOOR (WEST TOWER, DISPLAY 12-14

EXISTING 012 - 012
PROPOSED 012 - 012 40 Y R-2 1.5 2
3 UPPER LEVELS OF CLASS A APARTMENTS (EAST TOWER, DISPLAY 14)

EXISTING 013 - 014
PROPOSED 013 - 014 40 Y R-2 3 2
3 CLASS A APARTMENTS PER FLOOR (EAST TOWER, DISPLAY PH15-PH16)

EXISTING 013 - 014
PROPOSED 013 - 014 40 Y R-2 3 2
3 CLASS A APARTMENTS PER FLOOR (WEST TOWER, DISPLAY 15-16)

EXISTING 015 - 015
PROPOSED 015 - 015 40 Y R-2 3 2
3 CLASS A APARTMENTS(WEST TOWER, DISPLAY 17)

EXISTING 015 - 015
PROPOSED 015 - 015 1 100 Y F-2 2
MECHANICAL ROOF,ELECTRICAL CLOSET(EAST TOWER) (CONST R. DISPLAY T)

EXISTING 015 - 015
PROPOSED 015 - 015 53 40 Y R-2 2
AMENITY ROOF TERRACE ACCESSORY TO RESIDENTIAL(EAST TOWER) (CONST R. DISPLAY T)

EXISTING 016 - 016
PROPOSED 016 - 016 100 Y F-2 2
MECHANICAL (EAST TOWER, DISPLAY ROOF)

EXISTING 016 - 016
PROPOSED 016 - 016 40 Y R-2 3 2
3 CLASS A APARTMENTS(WEST TOWER, DISPLAY 18)

EXISTING 017 - 017
PROPOSED 017 - 017 3 100 Y F-2 2
ELEVATOR MACHINE ROOM(EAST TOWER) (DISPLAY ROOF)

EXISTING 017 - 017
PROPOSED 017 - 017 40 Y R-2 3 2
3 CLASS A APARTMENTS(WEST TOWER, DISPLAY 19)

EXISTING 018 - 018
PROPOSED 018 - 018 40 Y R-2 2 2
2 CLASS A APARTMENTS(WEST TOWER, DISPLAY 20)

EXISTING 019 - 019
PROPOSED 019 - 019 40 Y R-2 2 2
2 CLASS A APARTMENTS(WEST TOWER, DISPLAY 21)

EXISTING 020 - 020
PROPOSED 020 - 020 40 Y R-2 2 2
2 CLASS A APARTMENTS(WEST TOWER, DISPLAY 22)

EXISTING 021 - 021
PROPOSED 021 - 021 40 Y R-2 1 2
CLASS A APARTMENT (WEST TOWER, DISPLAY PH23)

EXISTING 022 - 022
PROPOSED 022 - 022 40 Y R-2 1 2
CLASS A APARTMENT (WEST TOWER, DISPLAY PH24)

EXISTING 023 - 023
PROPOSED 023 - 023 40 Y R-2 1 2
CLASS A APARTMENT(WEST TOWER, DISPLAY PH25)

EXISTING 024 - 024
PROPOSED 024 - 024 12 100 Y F-2 2
MECHANICAL ROOMS,BOILER ROOM(WEST TOWER, DISPLAY R1)

EXISTING 025 - 025
PROPOSED 025 - 025 12 100 Y F-2 2
MECHANICAL ROOMS(WEST TOWER, DISPLAY R2)

EXISTING 026 - 026
PROPOSED 026 - 026 5 100 Y F-2 2
MECHANICAL ROOM,ELEVATOR MACHINE ROOMS(WEST TOWER, DISPLAY R3)

EXISTING ROF -
PROPOSED ROF - 100 Y F-2 2
ROOF OF BULKHEAD(EAST TOWER)

EXISTING ROF -
PROPOSED ROF - 100 Y F-2 2
ROOF OF BULKHEAD(WEST TOWER)

C of O Comments:
THIS BUILDING IS LOCATED IN AE FLOOD ZONE. PER NYC 2014 BUILDING CODE, APPENDIX G, DESIGNATION G304.1.2 NONRESIDENTIAL (FOR FLOOD ZONE PURPOSES): ALL DWELLING UNITS AND ESSENTIAL MECHANICAL SYSTEMS TO BE LOCATED ABOVE DFE . THE CELLAR AND PORTIONS OF THE FIRST FLOOR OF THIS BUILDING ARE BELOW THE DFE. THESE AREAS BELOW THE DFE WILL BE DRY FLOODPROOFED AND REMOVABLE FLOOD BARRIERS WILL BE READILY INSTALLED AS REQUIRED AS PER SECTION G604.1.2.2 WITH ALL REQUIRED CERTIFICATIONS AND INSPECTIONS. ALL
REQUIRED FLOOD EGRESS EXIT DISCHARGES FROM THE MAIN RESIDENTIAL AREAS ARE LOCATED ABOVE THE DFE.
THESE PREMISES HAVE BEEN RECORDED IN THE CITY REGISTER UNDER CRFN# 2019000127834, #2019000127835, #2019000127836 AND #2022000397313.
ACCESSORY USES IN THIS BUILDING ARE RESTRICTED TO RESIDENTIAL OCCUPANTS OF THE BUILDING AND THEIR GUEST FOR WHOM NO ADMISSION OR MEMBERHSIP FEES MAY BE CHARGED.
FLOOD RESISTANT GLAZING TO BE INSTALLED AT STOREFRONT. (126.58 LF ALONG THE WEST FACADE, 144.08 LF ALONG THE NORTH FACADE, 17.91 LF ALONG THE NORTH AND WEST WEST SIDES OF THE INNER COURTYARD.) FLOOD RESISTANT GLAZING SYSTEM LIST OF MATERIALS: ALUMINUM EXTRUDED PROFILE, ALUMINUM PRESSWORK, STAINLESS STEEL FASTNERS, SCR GASKET (SILICONE COMPATIBLE EPDM), DOUBLE GLAZED GLASS, FIBER INSULATION, WATERPROOFING MEMBRANE, PP SHIMS, WEATHERSEAL SILICONE, MS POLYMER ADHESIVE, STEEL.


If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.

BIS Menu  |  Schedule A