NYC Department of Buildings | ||
Schedule 'A' |
Premises: 242 WEST 53 STREET MANHATTAN | Job No: 121185966 | |||
BIN: 1080868 Block: 1024 Lot: 52 | Doc No: 01 | Job Type: NB - NEW BUILDING |
Comments | ||||||||
EXISTING / PROPOSED |
FLOORS FRM - TO |
NO. PERS |
LIVE LOAD |
2022/2014/2008 Code? |
OCC GRP |
UNITS |
ZONE USE |
|
EXISTING | SUB - | |||||||
PROPOSED | SUB - | 7 | OG | Y | S-2 | 2 | ||
TENANT STORAGE | ||||||||
EXISTING | SUB - | |||||||
PROPOSED | SUB - | 9 | OG | Y | S-2 | 2 | ||
BIKE STORAGE ROOMS (217 BIKES) | ||||||||
EXISTING | SUB - | |||||||
PROPOSED | SUB - | 2 | OG | Y | F-2 | 2 | ||
MECHANICAL ROOMS | ||||||||
EXISTING | SUB - | |||||||
PROPOSED | SUB - | 69 | OG | Y | S-2 | 12 | ||
PUBLIC PARKING GARAGE FOR 104 CARS. | ||||||||
EXISTING | CEL - | |||||||
PROPOSED | CEL - | 5 | 100 | Y | S-1 | 2 | ||
TRASH COMPACTOR ROOM | ||||||||
EXISTING | CEL - | |||||||
PROPOSED | CEL - | 8 | 100 | Y | F-2 | 2 | ||
MECHANICAL ROOMS | ||||||||
EXISTING | CEL - | |||||||
PROPOSED | CEL - | 2 | 100 | Y | S-2 | 2 | ||
TENANT STORAGE ROOMS | ||||||||
EXISTING | CEL - | |||||||
PROPOSED | CEL - | 10 | 100 | Y | R-2 | 2 | ||
LAUNDRY ROOM | ||||||||
EXISTING | CEL - | |||||||
PROPOSED | CEL - | 2 | 100 | Y | B | 2 | ||
SUPER'S OFFICE | ||||||||
EXISTING | CEL - | |||||||
PROPOSED | CEL - | 5 | 100 | Y | F-2 | 2 | ||
SUPER'S WORKSHOP | ||||||||
EXISTING | CEL - | |||||||
PROPOSED | CEL - | 72 | 100 | Y | S-2 | 12 | ||
PUBLIC PARKING GARAGE FOR 80 CARS | ||||||||
EXISTING | 001 - 001 | |||||||
PROPOSED | 001 - 001 | 0 | 100 | Y | R-2 | 2 | ||
RESIDENTIAL LOBBY | ||||||||
EXISTING | 001 - 001 | |||||||
PROPOSED | 001 - 001 | 30 | 100 | Y | B | 6 | ||
BUSINESS OFFICES | ||||||||
EXISTING | 001 - 001 | |||||||
PROPOSED | 001 - 001 | 4 | 100 | Y | S-2 | 2 | ||
PACKAGE ROOM | ||||||||
EXISTING | 001 - 001 | |||||||
PROPOSED | 001 - 001 | 59 | 100 | Y | B | 4A | ||
TREATMENT HEALTHCARE FACILITIES | ||||||||
EXISTING | 001 - 001 | |||||||
PROPOSED | 001 - 001 | 103 | 100 | Y | M | 6 | ||
RETAIL 3 | ||||||||
EXISTING | 001 - | |||||||
PROPOSED | 001 - | 97 | 100 | Y | M | 6 | ||
RETAIL 2 | ||||||||
EXISTING | MZ1 - | |||||||
PROPOSED | MZ1 - | 7 | 100 | Y | F-2 | 2 | ||
MECHANICAL ROOM | ||||||||
EXISTING | MZ1 - | |||||||
PROPOSED | MZ1 - | 33 | 100 | Y | B | 4A | ||
TREATMENT HEALTHCARE FACILITIES | ||||||||
EXISTING | 002 - 002 | |||||||
PROPOSED | 002 - 002 | 60 | 100 | Y | R-2 | 2 | ||
ACCESSORY USE OUTDOOR TERRACE #1 | ||||||||
EXISTING | 002 - 002 | |||||||
PROPOSED | 002 - 002 | 40 | 100 | Y | R-2 | 2 | ||
ACCESSORY USE LOUNGE | ||||||||
EXISTING | 002 - 002 | |||||||
PROPOSED | 002 - 002 | 1 | 100 | Y | F-2 | 2 | ||
MECHANICAL ROOM | ||||||||
EXISTING | 002 - 002 | |||||||
PROPOSED | 002 - 002 | 15 | 100 | Y | R-2 | 2 | ||
ACCESSORY USE OUTDOOR TERRACE #2 | ||||||||
EXISTING | 002 - 002 | |||||||
PROPOSED | 002 - 002 | 53 | 100 | Y | R-2 | 2 | ||
ACCESSORY USE FITNESS CENTER | ||||||||
EXISTING | 002 - 002 | |||||||
PROPOSED | 002 - 002 | 30 | 282 | Y | R-2 | 2 | ||
ACCESSORY USE SWIMMING POOL | ||||||||
EXISTING | 002 - 002 | |||||||
PROPOSED | 002 - 002 | 22 | 100 | Y | R-2 | 2 | ||
ACCESSORY USE BASKETBALL COURT | ||||||||
EXISTING | 002 - 002 | |||||||
PROPOSED | 002 - 002 | 2 | 100 | Y | R-2 | 2 | ||
ACCESSORY USE SAUNA (WOMANS LOCKER ROOM) | ||||||||
EXISTING | 002 - 002 | |||||||
PROPOSED | 002 - 002 | 2 | 100 | Y | R-2 | 2 | ||
ACCESSORY USE SAUNA (MENS'S LOCKER ROOM) | ||||||||
EXISTING | 003 - 003 | |||||||
PROPOSED | 003 - 003 | 60 | 100 | Y | R-2 | 2 | ||
ACCESSORY USE OUTDOOR TERRACE | ||||||||
EXISTING | 003 - 003 | |||||||
PROPOSED | 003 - 003 | 73 | 100 | Y | R-2 | 2 | ||
ACCESSORY USE LOUNGE | ||||||||
EXISTING | 003 - 003 | |||||||
PROPOSED | 003 - 003 | 73 | 100 | Y | R-2 | 2 | ||
ACCESSORY USE CLUB ROOM | ||||||||
EXISTING | 003 - 003 | |||||||
PROPOSED | 003 - 003 | 18 | 100 | Y | R-2 | 2 | ||
PRIVATE DINING EPICUREAN LOUNGE. | ||||||||
EXISTING | 003 - 003 | |||||||
PROPOSED | 003 - 003 | 4 | 100 | Y | R-2 | 2 | ||
ACCESSORY USE GOLF SIMULATOR | ||||||||
EXISTING | MZ3 - | |||||||
PROPOSED | MZ3 - | 51 | 100 | Y | R-2 | 2 | ||
ACCESSORY USE OUTDOOR TERRACE | ||||||||
EXISTING | MZ3 - | |||||||
PROPOSED | MZ3 - | 15 | 100 | Y | R-2 | 2 | ||
LOBBY | ||||||||
EXISTING | 004 - 004 | |||||||
PROPOSED | 004 - 004 | 40 | Y | R-2 | 8 | 2 | ||
APARTMENTS | ||||||||
EXISTING | 004 - 004 | |||||||
PROPOSED | 004 - 004 | 7 | 100 | Y | F-2 | 2 | ||
MECHANICAL ROOM | ||||||||
EXISTING | 005 - 005 | |||||||
PROPOSED | 005 - 005 | 40 | Y | R-2 | 8 | 2 | ||
APARTMENTS | ||||||||
EXISTING | 005 - 005 | |||||||
PROPOSED | 005 - 005 | 1 | 100 | Y | F-2 | 2 | ||
MECHANICAL ROOM CATWALK (LEVEL 004 MECHANICAL ROOM) | ||||||||
EXISTING | 006 - 006 | |||||||
PROPOSED | 006 - 006 | 40 | Y | R-2 | 8 | 2 | ||
APARTMENTS | ||||||||
EXISTING | 007 - 007 | |||||||
PROPOSED | 007 - 007 | 40 | Y | R-2 | 8 | 2 | ||
APARTMENTS | ||||||||
EXISTING | 007 - 007 | |||||||
PROPOSED | 007 - 007 | 7 | 100 | Y | F-2 | 2 | ||
DAS ROOM | ||||||||
EXISTING | 008 - 015 | |||||||
PROPOSED | 008 - 015 | 40 | Y | R-2 | 10 | 2 | ||
APARTMENTS EACH FLOOR | ||||||||
EXISTING | 016 - 030 | |||||||
PROPOSED | 016 - 030 | 40 | Y | R-2 | 9 | 2 | ||
APARTMENTS EACH FLOOR | ||||||||
EXISTING | 031 - 031 | |||||||
PROPOSED | 031 - 031 | 40 | Y | R-2 | 3 | 2 | ||
APARTMENTS | ||||||||
EXISTING | 031 - 031 | |||||||
PROPOSED | 031 - 031 | 7 | 100 | Y | F-2 | 2 | ||
MECHANICAL ROOMS | ||||||||
EXISTING | 031 - 031 | |||||||
PROPOSED | 031 - 031 | 40 | Y | R-2 | 0.5 | 2 | ||
LOWER PART OF DUPLEX APARTMENT | ||||||||
EXISTING | 032 - 032 | |||||||
PROPOSED | 032 - 032 | 40 | Y | R-2 | 2 | 2 | ||
APARTMENTS | ||||||||
EXISTING | 032 - 032 | |||||||
PROPOSED | 032 - 032 | 2 | 100 | Y | F-2 | 2 | ||
MECHANICAL ROOMS | ||||||||
EXISTING | 032 - 032 | |||||||
PROPOSED | 032 - 032 | 40 | Y | R-2 | 0.5 | 2 | ||
UPPER PART OF DUPLEX APARTMENT | ||||||||
EXISTING | 033 - 052 | |||||||
PROPOSED | 033 - 052 | 40 | Y | R-2 | 7 | 2 | ||
APARTMENTS EACH FLOOR | ||||||||
EXISTING | 053 - 057 | |||||||
PROPOSED | 053 - 057 | 40 | Y | R-2 | 6 | 2 | ||
APARTMENTS EACH FLOOR | ||||||||
EXISTING | 058 - 058 | |||||||
PROPOSED | 058 - 058 | 40 | Y | R-2 | 2 | 2 | ||
APARTMENTS | ||||||||
EXISTING | 058 - 058 | |||||||
PROPOSED | 058 - 058 | 40 | Y | R-2 | 0.5 | 2 | ||
LOWER PART OF DUPLEX APARTMENT | ||||||||
EXISTING | 059 - 059 | |||||||
PROPOSED | 059 - 059 | 40 | Y | R-2 | 0.5 | 2 | ||
UPPER PART OF DUPLEX APARTMENT | ||||||||
EXISTING | 059 - 059 | |||||||
PROPOSED | 059 - 059 | 10 | 100 | Y | F-2 | 2 | ||
MECHANICAL ROOMS | ||||||||
EXISTING | 060 - 060 | |||||||
PROPOSED | 060 - 060 | 60 | 100 | Y | R-2 | 2 | ||
ACCESSORY USE OUTDOOR POOL DECK | ||||||||
EXISTING | 060 - 060 | |||||||
PROPOSED | 060 - 060 | 57 | 100 | Y | R-2 | 2 | ||
ACCESSORY USE LOUNGE | ||||||||
EXISTING | 060 - 060 | |||||||
PROPOSED | 060 - 060 | 12 | 290 | Y | R-2 | 2 | ||
ACCESSORY USE OUTDOOR SWIMMING POOL. | ||||||||
EXISTING | 061 - 061 | |||||||
PROPOSED | 061 - 061 | 1 | 100 | Y | F-2 | 2 | ||
MECHANICAL ROOMS | ||||||||
EXISTING | 061 - 061 | |||||||
PROPOSED | 061 - 061 | 100 | Y | F-2 | 2 | |||
OPEN ROOF | ||||||||
EXISTING | 062 - 062 | |||||||
PROPOSED | 062 - 062 | 3 | 100 | Y | F-2 | 2 | ||
MECHANICAL ROOM | ||||||||
C of O Comments: | ||||||||
TRANSFER OF DEVELOPMENT RIGHTS AND NOTICE OF RESTRICTIONS PURSUANT TO SECTION 81-74 OF THE ZONING RESOLUTION OF THE CITY OF NEW YORK RECORDED AT THE CITY REGISTER UNDER CRFN 2014000175543 & 2014000175542. SPECIAL PERMIT #C170112ZSM APPROVED BY CITY PLANNING COMMISSION FOR PUBLIC PARKING GARAGE |