| NYC Department of Buildings | ||
| Query Inspection Results:1-15-30671 | ||
| Premises: 61 TIEMANN PLACE MANHATTAN | Job No: 122292768 01 | ||
| BIN: 1059881 Block: 1995 Lot: 5 | Permit Number: 122292768 | ||
| Licensee: P 000599 | Permit Type: LA4 |
| Floor - Apts - Insp Area: 3,5 - 38,55 - |
| Work Description: FILING TO CLEAR VIOLATION #35115340Y. DUE TO GAS LEAK & CON ED SHUTDOWN REPLAC |
| E APPROX 250' OF 2" & 70' OF 1 1/2" GAS PIPING IN THE CELLAR. & REPLACE (10) L |
| Inspector Badge: | 2557 | Date of Inspection: | 09/25/2015 | Time Scheduled: | 10:04 ACTUAL |
| Inspection Reference #: | 0001382037 | Status: | INSPECTION CONDUCTED | Type: | I - INSPECTION |
| Accela Inspection #: | |||||
| RESULTS: | |||||
| FLOOR | REF NO | SYSTEM | COMPONENT | TEST / INSPECTION | RESULT |
| 003 | 5276461 0 | 7 - GAS | 7201 - GAS PIPING | A72A - GAS AUTHORIZATION | PASS |
| 005 | 5276465 0 | 7 - GAS | 7201 - GAS PIPING | I72B - GAS PIPING ROUGHING | PASS |
| 003 | 5268736 0 | 7 - GAS | 7201 - GAS PIPING | T72A - GAS PIPING GAS TEST LOW | PASS |
| 003 | 5268737 0 | 7 - GAS | 7100 - GAS-FIXTURES | I71A - GAS SYSTEM FINISH | PASS |
| 005 | 5276463 0 | 7 - GAS | 7201 - GAS PIPING | A72A - GAS AUTHORIZATION | PASS |
| 005 | 5276466 0 | 7 - GAS | 7201 - GAS PIPING | T72A - GAS PIPING GAS TEST LOW | PASS |
| 005 | 5276460 0 | 7 - GAS | 7100 - GAS-FIXTURES | I71A - GAS SYSTEM FINISH | PASS |
| 003 | 5268735 0 | 7 - GAS | 7201 - GAS PIPING | I72B - GAS PIPING ROUGHING | PASS |
| COMMENTS: TOTAL: 3 |
| GAS DETAILS - AUTHORIZED FOR THE FOLLOWING END USES: | |||||||||||||
| METER FLOOR | REF NO | TOTAL METERS | TOTAL RISERS | NEW METER | HEAT | COOK | COIL | HOT WATER |
DRYER | BOILER PILOT |
FIRE PLACE |
HVAC | OTHER |
| 003 | 5276461 0 | 1 | 1 | Y | |||||||||
| METER LOCATION: APT 38 ON 3 FL RISER LOCATION: FLOOR 3 TO 3 | |||||||||||||
| 005 | 5276463 0 | 1 | 1 | Y | |||||||||
| METER LOCATION: APT 55 ON 5 FL RISER LOCATION: FLOOR 5 TO 5 FL | |||||||||||||