Query Inspection Results:4-06-23586
Premises: 53-21 SKILLMAN AVENUE QUEENS Job No: 402049403 01
BIN: 4028432    Block: 1238    Lot: 49 Permit Number: 402049403
Licensee: P  001626 Permit Type: ARA
GAS SERVICE  |  COMMENTS

Floor - Apts - Insp Area: BASEMENT - -
Work Description: CONNECT GAS FIRED BLR, RUNNING ONE 1/4" GAS LINE TO NEW METER 55FT. CHIMNEYLIN
ED & IN GOOD CONDITION, VENTING UNIT TO EXISTING CHIMNEY TO ROOF. INSTALLTWO W

Inspector Badge: 2152 Date of Inspection: 11/01/2006 Time Scheduled: 12:41 ACTUAL
Inspection Reference #: 0000463916 Status: INSPECTION CONDUCTED Type: I - INSPECTION
Accela Inspection #: 0000000000000000337127


RESULTS:
FLOOR REF NO SYSTEM COMPONENT TEST / INSPECTION RESULT
CEL 1249781 0 7 - GAS 7100 - GAS-FIXTURES I71A - GAS SYSTEM FINISH PASS
CEL 1263377 0 7 - GAS 7201 - GAS PIPING A72A - GAS AUTHORIZATION PASS
CEL 1249779 0 7 - GAS 7201 - GAS PIPING I72B - GAS PIPING ROUGHING PASS
CEL 1249780 0 7 - GAS 7201 - GAS PIPING T72A - GAS PIPING GAS TEST LOW PASS
(*) Changes to these tests after the initial inspection scheduling may not be reflected on this website.

COMMENTS: TOTAL: 1      

GAS DETAILS - AUTHORIZED FOR THE FOLLOWING END USES:
METER FLOOR REF NO TOTAL METERS TOTAL RISERS NEW METER HEAT COOK COIL HOT
WATER
DRYER BOILER
PILOT
FIRE
PLACE
HVAC OTHER
CEL 1263377 0 1 1 X       Y          
  METER LOCATION: CELLAR      RISER LOCATION: CEL TO CEL