BIS Menu  |  Insp. Results   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Query Inspection Results:1-14-13343
Premises: 385 EDGECOMBE AVENUE MANHATTAN Job No: 140111723 01
BIN: 1061183    Block: 2054    Lot: 49 Permit Number: 140111723
Licensee: P  000928 Permit Type: LAA
GAS SERVICE  |  COMMENTS

Floor - Apts - Insp Area: CEL - -
Work Description: INSTALL NEW GAS SERVICE, GAS METER AND APPROXIMATELY 100 FEET OF 4 INCH GAS PI
PING AND CONNECT TO EXISTING GAS/OIL BURNER: ICI MMG-42P, MEA #159-74 NYC BOI

Inspector Badge: 100P Date of Inspection: 05/02/2014 Time Scheduled: 1000 SCHEDULED
Inspection Reference #: 0001233057 Status: INSPECTION CONDUCTED Type: S - SELF-CERT
Accela Inspection #:


RESULTS:
FLOOR REF NO SYSTEM COMPONENT TEST / INSPECTION RESULT
CEL 4653682 0 7 - GAS 7201 - GAS PIPING A72A - GAS AUTHORIZATION PASS
CEL 4653680 0 3 - WATER & SANITARY 3100 - W&S-FIXTURES I31A - W&S SYSTEM FINISH PASS
CEL 4653681 0 7 - GAS 7100 - GAS-FIXTURES I71A - GAS SYSTEM FINISH PASS
CEL 4641152 0 7 - GAS 7201 - GAS PIPING T72A - GAS PIPING GAS TEST LOW PASS
CEL 4641151 0 7 - GAS 7201 - GAS PIPING I72B - GAS PIPING ROUGHING PASS
(*) Changes to these tests after the initial inspection scheduling may not be reflected on this website.

COMMENTS: TOTAL: 1      

GAS DETAILS - AUTHORIZED FOR THE FOLLOWING END USES:
METER FLOOR REF NO TOTAL METERS TOTAL RISERS NEW METER HEAT COOK COIL HOT
WATER
DRYER BOILER
PILOT
FIRE
PLACE
HVAC OTHER
CEL 4653682 0 1 1   Y   Y            
  METER LOCATION: CELLAR      RISER LOCATION: CELLAR


If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.

BIS Menu  |  Insp. Results