| CODE | FLOOR | REF NO | SYSTEM | TEST / INSPECTION | INSPECTION DATE |
RESOLVING INSPECTION |
RESOLVED DATE |
| NEWOBJ | 000 | 0004189317 | 0 - ALL | I00B - NOT APPLICABLE | 05/01/2013 | 3-13-07258 | 07/19/2013 |
| Description: MODIFY PLANS TO SHOW STORM HOUSE TRAP (NOT RUNNING TRAP) AND RISER FROM CELLAR,1,2,3,4,ROOF. | |||||||
| DOBOBJ | 004 | 0004189322 | 3 - WATER & SANITARY | I32B - W&S PIPING ROUGHING | 05/01/2013 | 3-13-07258 | 07/19/2013 |
| Description: 4TH FLR - HOT WATER RETURN LINE -NEEDS TO BE AT FURTEST FIXTURE. (NOT 25 FEET AWAY FROM IT) | |||||||
| DOBOBJ | 003 | 0004189325 | 3 - WATER & SANITARY | I32B - W&S PIPING ROUGHING | 05/01/2013 | 3-13-07258 | 07/19/2013 |
| Description: 3RD FLR FLOOR DRAIN NEEDS TRAP PRIMER | |||||||
| NEWOBJ | 000 | 0004189316 | 0 - ALL | I00B - NOT APPLICABLE | 05/01/2013 | 3-13-07258 | 07/19/2013 |
| Description: ROOF - MODIFY PLANS AND APPLICATION TO SHOW 3 ROOF DRAINS. | |||||||
| DOBOBJ | 004 | 0004189321 | 3 - WATER & SANITARY | I32B - W&S PIPING ROUGHING | 05/01/2013 | 3-13-07258 | 07/19/2013 |
| Description: 4TH FLR FLOOR DRAIN NEEDS TRAP PRIMER | |||||||
| DOBOBJ | 003 | 0004189324 | 3 - WATER & SANITARY | I32B - W&S PIPING ROUGHING | 05/01/2013 | 3-13-07258 | 07/19/2013 |
| Description: 3RD FLR FLOOR DRAIN NEEDS VENT (NOT WITHIN 15 FROM A VENTED LINE) | |||||||
| DOBOBJ | 004 | 0004189320 | 3 - WATER & SANITARY | I32B - W&S PIPING ROUGHING | 05/01/2013 | 3-13-07258 | 07/19/2013 |
| Description: 4TH FLR FLOOR DRAIN - NEEDS VENT OVER 15FEET FROMA VENTED LINE. | |||||||
| DOBOBJ | 003 | 0004189323 | 3 - WATER & SANITARY | I32B - W&S PIPING ROUGHING | 05/01/2013 | 3-13-07258 | 07/19/2013 |
| Description: 3RD FLR - HW RETURN LINE NEEDS TO BE "AT" FURTHERMORE FIXTURE ( NOT 30FEET AWAY FROM IT) | |||||||
| DOBOBJ | 004 | 0004189319 | 3 - WATER & SANITARY | I32B - W&S PIPING ROUGHING | 05/01/2013 | 3-13-07258 | 07/19/2013 |
| Description: 4TH FLR - WASHER MACHINE STANDPIPE (MIN 3INCH AFTER TRAP) | |||||||
| DOBOBJ | 001 | 0004189318 | 7 - GAS | I72B - GAS PIPING ROUGHING | 05/01/2013 | 3-13-07258 | 07/19/2013 |
| Description: 1STFLR - GAS PIPING IN PUBLIC HALLWAY (2ND AND 3RD FLR GAS RISERS) | |||||||