Electrical Application Details for App #: Z162677
Premises: 2 RIVERSIDE BOULEVARD MANHATTAN BIN: 1089741     Block: 1171   Lot: 155
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 10 RIVERSIDE BLVD Census Tract:   151 Health Area:  3900
GROUND FLOOR Admin Area:   Z - UPPER MANHATTAN Inspection Area:   E
NEW YORK, NY 10069 Community Board:   107
Special Place Name:   RIVERSIDE CENTER BUILDING 3
Related Job Number:    121192976
DOB Cross Street(s):   WEST 59 STREET,    WEST 61 STREET
Status:   C - JOB IS SIGNED OFF 05/24/2021
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  09/15/2017 7:20 PM
Application Entered:   09/15/2017 Job Start Date:   09/16/2017
Last Change:   05/24/2021 Job End Date:   04/01/2019
Appointment Status:   
Last Inspection By:   ADAM ADAMSKI       On     05/22/2021      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  

License #: 011289 Licensee Name: PETER BORDUCCI
Firm: 002860 Firm Name: SOLAR ELEC. SYSTEMS, INC.
Firm Phone: 718-824-7000  Firm Address: 1402 BLONDELL AVENUE BRONX NY 10461 

Work Started or Filed by Others: NO
Work Category:   N - NEW BUILDING Work To Be Done:  
W - SIDEWALK SHED WIRING & LIGHTING
Total Fee:  $42.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   YES
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   Z - Commercial/Residential (36  Stores, 288 Apartments)
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: JOHN GAGNIER
Owner Business Name: RCB 3 NOMINEE LLC,A DELAW
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
GND    10        10             
Buildings Total 10        10                
Total Units : 20 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  SIDEWALK BRIDGE LIGHTS

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Z162677
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 05/22/2021 05/24/2021 ASK C (13) (0) Y
INSPECTION COMMENTS: PASS. INSPECTION COMPLETED. SIDEWALK SHED REMOVED. . ATOI GIACOMO MARCHESE