Electrical Application Details for App #: Z162516
Premises: 1012 RIVERSIDE DRIVE MANHATTAN BIN: 1076746     Block: 2139   Lot: 1
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 173 FORT WASHINGTON AV Census Tract:   255 Health Area:  8700
2ND FLOOR Admin Area:   Z - UPPER MANHATTAN Inspection Area:   A
NEW YORK, NY 10032 Community Board:   112
Special Place Name:   HEART HOSPITAL
DOB Cross Street(s):   WEST 165 STREET,    WEST 168 STREET
Status:   C - JOB IS SIGNED OFF 02/01/2018
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  09/07/2017 2:04 PM
Application Entered:   09/07/2017 Job Start Date:   09/08/2017
Last Change:   02/01/2018 Job End Date:   09/07/2018
Appointment Status:   
Last Inspection By:   GARY MCCALLA       On     01/08/2018      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  

License #: 010517 Licensee Name: ANTHONY J SCALA, JR.
Firm: 000898 Firm Name: LOWY & DONNATH INC.
Firm Phone: 718-392-8222  Firm Address: 10-37 49TH AVENUE LONG ISLAND CITY NY 11101 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $41.25
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   I - Hospital Or Health Facility
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: JOE KRAUS
Owner Business Name: NYPH
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
002                 
Buildings Total                 
Total Units : 15 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  HEART HOSPITAL HC2 OFFICE RENOVATION

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Z162516
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 01/08/2018 01/08/2018 GYM C (60) (0) Y
INSPECTION COMMENTS: PASS