NYC Department of Buildings
Electrical Application Details for App #: Z161617
Premises: 131 RIVERSIDE DRIVE MANHATTAN BIN: 1033903     Block: 1247   Lot: 1
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 131 RIVERSIDE DR Census Tract:   171 Health Area:  3400
1 ST FLOOR Admin Area:   Z - UPPER MANHATTAN Inspection Area:   D
NEW YORK, NY 10024 Community Board:   107
DOB Cross Street(s):   WEST 85 STREET,    WEST 86 STREET
Status:   C - JOB IS SIGNED OFF 04/18/2018
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  07/10/2017 12:54 PM
Application Entered:   07/10/2017 Job Start Date:   07/11/2017
Last Change:   04/18/2018 Job End Date:   08/11/2017
Appointment Status:   
Last Inspection By:   CAMPBELL, C       On     04/18/2018      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 010159 Licensee Name: FRANK J FODERA
Firm: 002012 Firm Name: PAPPAS & FODERA ELECT'L
Firm Phone: 718-634-2211  Firm Address: 260 BEACH 116TH ST 2ND FLOOR CORP ROCKAWAY PARK NY 11694 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $67.75
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: BILL TSOUMAS
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  1  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
001    22  20  14               
Buildings Total 22  20  14                  
Total Units : 61 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 03/02/2018
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Z161617
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 02/27/2018 02/27/2018 MLF J (30) (0) Y
INSPECTION COMMENTS: JOB NOT COMPLETE ( CON ED CANCELLED APPOINTMENT EARLIER IN DAY )
 
(2) 03/01/2018 03/02/2018 AYC V (85) (8)
INSPECTION COMMENTS: FAIL
 
(3) 04/18/2018 04/18/2018 CLC C R (30) (0)
INSPECTION COMMENTS: INSPECTION PASS

OBJECTION FOR APPLICATION #: Z161617
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (128) NEUTRAL IS GROUNDED BEYOND LOAD SIDE OF SERVICE SWITCH
(FLOOR: 001)NEUTRAL BAR IS GROUNDED IN THE APARTMENT CIRCUIT BREAKER PANEL. ART.250.24(C)(5)
RSLV 03/01/2018 03/01/2018 04/18/2018
 
002 (132) EQUIPMENT/MATERIAL IS NOT PROPERLY GROUNDED
(FLOOR: 001)NO GROUND WIRE PROVIDED IN THE GREENFIELD FOR APARTMENT RISER. ART.250.118
RSLV 03/01/2018 03/01/2018 04/18/2018
 
003 (164) BOXES OR FITTINGS ARE MISSING
(FLOOR: 001)WORK STILL IN PROGRESS. JUNCTION BOXES MISSING. ART. 314
RSLV 03/01/2018 03/01/2018 04/18/2018
 
004 (239) GFCI HAS NOT BEEN PROVIDED
(FLOOR: 001) ISLAND RECEPTACLE IS NOT GFCI PROTECTED. ART. 210.52
RSLV 03/01/2018 03/01/2018 04/18/2018
 
005 ( 33) KNOCKOUTS ARE NOT CLOSED IN OUTLET BOX
(FLOOR: 001) KO'S MISSING IN KITCHEN OUTLET BOXES. ART. 110.12(A)
RSLV 03/01/2018 03/01/2018 04/18/2018
 
006 (999) OTHER
(FLOOR: 001)COMMON RISER JUNCTION BOX IS NOT READILY ACCESSIBLE. ART. 314.29
RSLV 03/01/2018 03/01/2018 04/18/2018
 
007 (999) OTHER
(FLOOR: 001) GROUND BARS NOT PROPERLY INSTALLED. ART. 250.126
RSLV 03/01/2018 03/01/2018 04/18/2018
 
008 (999) OTHER
(FLOOR: 001)LIGHT FIXTURE IN THE BATHROOM IS NOT MARKED FOR WET LOCATIONS. ART.410.10(D)
RSLV 03/01/2018 03/01/2018 04/18/2018