| BUILDING OVERVIEW |
Are Feeders Being Installed? : No |
| (If feeders are being installed, provide a wiring diagram and calculations at the time of inspection) |
| Building Overview Work Items |
QUANTITY |
DESCRIPTION |
| SERVICE SWITCHES |
|
| A. Up to 100 AMPS |
0 |
|
| B. 101 Up to 200 AMPS |
0 |
|
| C. 201 Up to 600 AMPS |
0 |
|
| D. 601 Up to 1200 AMPS |
0 |
|
| E. Over 1200 AMPS |
0 |
|
| SER. ENT. & FDR COND (EACH SET) |
|
| A. Up to #2 CONDUCTOR |
1 |
|
| B. Over #2 to 1/0 |
0 |
|
| C. Over 1/0 to 250 MCM |
0 |
|
| D. Over 250 MCM |
0 |
|
| PANELS |
|
| A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs |
0 |
|
| B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs |
0 |
|
| C. 3 Phase Up to 225 AMPS |
0 |
|
| D. 3 Phase Over 225 AMPS |
0 |
|
| ELEVATORS / ESCALATORS / MATERIAL LIFTS |
|
| A. Total No. of Elevators / Escalators / Material Lifts |
0 |
|
| B. Each Additional 10 Floors Or Less |
0 |
|
| BOILER CONTROLS |
0 |
|
| OBJECTION ID |
OBJECTION CODE |
OBJECTION DESCRIPTION & COMMENTS |
STAT |
FIRST |
LATEST |
RESLVD |
| |
| 001 |
(128) |
NEUTRAL IS GROUNDED BEYOND LOAD SIDE OF SERVICE SWITCH (FLOOR: 001)NEUTRAL BAR IS GROUNDED IN THE APARTMENT CIRCUIT BREAKER PANEL. ART.250.24(C)(5) |
RSLV |
03/01/2018 |
03/01/2018 |
04/18/2018 |
| |
| 002 |
(132) |
EQUIPMENT/MATERIAL IS NOT PROPERLY GROUNDED (FLOOR: 001)NO GROUND WIRE PROVIDED IN THE GREENFIELD FOR APARTMENT RISER. ART.250.118 |
RSLV |
03/01/2018 |
03/01/2018 |
04/18/2018 |
| |
| 003 |
(164) |
BOXES OR FITTINGS ARE MISSING (FLOOR: 001)WORK STILL IN PROGRESS. JUNCTION BOXES MISSING. ART. 314 |
RSLV |
03/01/2018 |
03/01/2018 |
04/18/2018 |
| |
| 004 |
(239) |
GFCI HAS NOT BEEN PROVIDED (FLOOR: 001) ISLAND RECEPTACLE IS NOT GFCI PROTECTED. ART. 210.52 |
RSLV |
03/01/2018 |
03/01/2018 |
04/18/2018 |
| |
| 005 |
( 33) |
KNOCKOUTS ARE NOT CLOSED IN OUTLET BOX (FLOOR: 001) KO'S MISSING IN KITCHEN OUTLET BOXES. ART. 110.12(A) |
RSLV |
03/01/2018 |
03/01/2018 |
04/18/2018 |
| |
| 006 |
(999) |
OTHER (FLOOR: 001)COMMON RISER JUNCTION BOX IS NOT READILY ACCESSIBLE. ART. 314.29 |
RSLV |
03/01/2018 |
03/01/2018 |
04/18/2018 |
| |
| 007 |
(999) |
OTHER (FLOOR: 001) GROUND BARS NOT PROPERLY INSTALLED. ART. 250.126 |
RSLV |
03/01/2018 |
03/01/2018 |
04/18/2018 |
| |
| 008 |
(999) |
OTHER (FLOOR: 001)LIGHT FIXTURE IN THE BATHROOM IS NOT MARKED FOR WET LOCATIONS. ART.410.10(D) |
RSLV |
03/01/2018 |
03/01/2018 |
04/18/2018 |