BIS Menu  |  Property Profile  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: Z160891
Premises: 390 RIVERSIDE DRIVE MANHATTAN BIN: 1057323     Block: 1894   Lot: 31
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 390 RIVERSIDE DR Census Tract:   199 Health Area:  2310
APT. 4A Admin Area:   Z - UPPER MANHATTAN Inspection Area:   C
NEW YORK, NY 10025 Community Board:   109
DOB Cross Street(s):   BROADWAY,    PEDESTRIAN PATH
Status:   C - JOB IS SIGNED OFF 02/07/2018
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  05/26/2017 9:35 AM
Application Entered:   05/26/2017 Job Start Date:   05/26/2017
Last Change:   02/07/2018 Job End Date:   10/26/2017
Appointment Status:   
Last Inspection By:   MOSES, DANIEM       On     12/12/2017      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 010438 Licensee Name: SILVIO HONOVIC
Firm: 000244 Firm Name: BLUE RIBBON ELEC'L CONTRS
Firm Phone: 718-625-5000  Firm Address: 500 SMITH STREET BROOKLYN NY 11231 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $59.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: LUCIENNE MULLER
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  1  SINGLE PHASE
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
004  14               
Buildings Total 14                  
Total Units : 26 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 11/16/2017
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  KITCHEN RENOVATION ONLY|

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Z160891
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 11/02/2017 11/02/2017 MLF N (19) (0) Y
INSPECTION COMMENTS: CALLED OFFICE NO SHOW
 
(2) 11/15/2017 11/16/2017 EDB V (40) (5)
INSPECTION COMMENTS: SEE ATTACHMENT.
 
(3) 12/12/2017 12/12/2017 DNM C R (35) (0)
INSPECTION COMMENTS: OBJECTIONS REMOVED.

OBJECTION FOR APPLICATION #: Z160891
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 21) CONDUCTORS HAVE NOT BEEN PROPERLY DE-RATED
(FLOOR: 004) PANEL : OVER 10 CURRENT CONDUCTORS IN THE RACEWAY310.15 B2A
RSLV 11/15/2017 11/15/2017 12/12/2017
 
002 ( 22) FIXED EQUIPMENT IS NOT PROPERLY GROUNDED
(FLOOR: 004) RACEWAY MISSING GND AND SPLICE BOX250.118,112,122
RSLV 11/15/2017 11/15/2017 12/12/2017
 
003 ( 33) KNOCKOUTS ARE NOT CLOSED IN OUTLET BOX
(FLOOR: 004) K/O MISSING IN THE BOX 110.12
RSLV 11/15/2017 11/15/2017 12/12/2017
 
004 ( 42) BUSHINGS ARE MISSING OR LOOSE
(FLOOR: 004)# 4 AWG NO BUSHING 300.4
RSLV 11/15/2017 11/15/2017 12/12/2017
 
005 ( 53) GFCI HAS NOT BEEN PROVIDED
(FLOOR: 004) KITCHEN MISSING GFCI PROTECTION 210.8
RSLV 11/15/2017 11/15/2017 12/12/2017



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Property Profile  |  Electrical Inspection Work Order  |  Back