BIS Menu  |  Applications  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: Z160855
Premises: 772 ST NICHOLAS AVENUE MANHATTAN BIN: 1061156     Block: 2053   Lot: 114
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 772 ST NICHOLAS AV Census Tract:   231 Health Area:  0720
APT 68 Admin Area:   Z - UPPER MANHATTAN Inspection Area:   B
NEW YORK, NY 10031 Community Board:   109
DOB Cross Street(s):   WEST 148 STREET,    DONNELLON SQUARE
Status:   C - JOB IS SIGNED OFF 03/13/2018
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  05/24/2017 12:32 PM
Application Entered:   05/24/2017 Job Start Date:   05/24/2017
Last Change:   03/13/2018 Job End Date:   05/24/2018
Appointment Status:   
Last Inspection By:   MICHAEL QUERY       On     02/27/2018      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 009113 Licensee Name: MARTIN WEINSTEIN
Firm: 000796 Firm Name: JOSEPH WEINSTEIN ELECTRIC
Firm Phone: 718-843-5555  Firm Address: 94-24 88TH STREET CORP OZONE PARK NY 11416 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $68.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup:
Owner Business Name: RCM ROOFING CORP
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  1  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
006  68  16  26    16             
Buildings Total 16  26    16                
Total Units : 64 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 01/25/2018
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Z160855
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 09/27/2017 09/27/2017 EDB V (75) (8)
INSPECTION COMMENTS: CONTRACTOR NO SHOW. NOT A FINAL INSPECTION.
 
(2) 12/19/2017 12/19/2017 MLF H X (27) (0) Y
INSPECTION COMMENTS: CONTRACTOR NOT FAMILIAR WITH JOB-----NOT AWARE OF PREVIOUS INSPECTION
 
(3) 01/24/2018 01/25/2018 JRP V Y (45) (3)
INSPECTION COMMENTS: FAIL
 
(4) 02/27/2018 02/28/2018 MQY C R (40) (0)
INSPECTION COMMENTS: RESOLVED PREVIOUS OBJECTIONS

OBJECTION FOR APPLICATION #: Z160855
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 24) ARMORED CABLES ARE NOT PROPERLY SECURED
(FLOOR: 006) KITCHEN
RSLV 09/27/2017 09/27/2017 01/24/2018
 
002 ( 25) ARMORED CABLES ARE NOT PROPERLY TERMINATED
(FLOOR: 006) KITCHEN
RSLV 09/27/2017 09/27/2017 01/24/2018
 
003 ( 29) OUTLET BOXES ARE NOT COVERED
(FLOOR: 006) OPEN BOXES
RSLV 09/27/2017 09/27/2017 01/24/2018
 
004 ( 46) PANEL HAS NOT BEEN PROVIDED WITH A DIRECTORY
(FLOOR: 006) NEW PANEL
RSLV 09/27/2017 09/27/2017 02/27/2018
 
005 (999) OTHER
(FLOOR: 006) NO RECEPTACLE PROVIDED ISLAND 210.52
RSLV 09/27/2017 09/27/2017 01/24/2018
 
006 (999) OTHER
(FLOOR: 006)NOT ALL RECEPTACLES ARE LISTED TAMPER RESISTANT TYPE 406.11
RSLV 09/27/2017 09/27/2017 01/24/2018
 
007 (999) OTHER
(FLOOR: 006) PANEL TRIM MISSING 110.2
RSLV 09/27/2017 09/27/2017 01/24/2018
 
008 (999) OTHER
(FLOOR: 006) MIN 2 20 AMP CIRCUITS REQ'D KITCHEN 210.11
RSLV 09/27/2017 09/27/2017 02/27/2018
 
009 (999) OTHER
(FLOOR: 006) BREAKERS NOT LISTED FOR PANEL 110.3(B)
RSLV 01/24/2018 01/24/2018 02/27/2018
 
010 (999) OTHER
(FLOOR: 006) BRICK WALL SPACE NEEDS A RECEPTACLE 210.52(A)
RSLV 01/24/2018 01/24/2018 02/27/2018
 
011 (999) OTHER
(FLOOR: 006) PENDENT LIGHTS OVER ISLAND NOT GROUNDED 250.118
RSLV 01/24/2018 01/24/2018 02/27/2018



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.