| BUILDING OVERVIEW |
Are Feeders Being Installed? : No |
| (If feeders are being installed, provide a wiring diagram and calculations at the time of inspection) |
| Building Overview Work Items |
QUANTITY |
DESCRIPTION |
| SERVICE SWITCHES |
|
| A. Up to 100 AMPS |
0 |
|
| B. 101 Up to 200 AMPS |
0 |
|
| C. 201 Up to 600 AMPS |
0 |
|
| D. 601 Up to 1200 AMPS |
0 |
|
| E. Over 1200 AMPS |
0 |
|
| SER. ENT. & FDR COND (EACH SET) |
|
| A. Up to #2 CONDUCTOR |
0 |
|
| B. Over #2 to 1/0 |
0 |
|
| C. Over 1/0 to 250 MCM |
0 |
|
| D. Over 250 MCM |
0 |
|
| PANELS |
|
| A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs |
0 |
|
| B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs |
1 |
100 AMP 1 PHASE MAIN LUG |
| C. 3 Phase Up to 225 AMPS |
0 |
|
| D. 3 Phase Over 225 AMPS |
0 |
|
| ELEVATORS / ESCALATORS / MATERIAL LIFTS |
|
| A. Total No. of Elevators / Escalators / Material Lifts |
0 |
|
| B. Each Additional 10 Floors Or Less |
0 |
|
| BOILER CONTROLS |
0 |
|
| OBJECTION ID |
OBJECTION CODE |
OBJECTION DESCRIPTION & COMMENTS |
STAT |
FIRST |
LATEST |
RESLVD |
| |
| 001 |
(176) |
INSTALLATION DOES NOT MEET CODE REQUIREMENTS (FLOOR: 011)408.36 100A BACKFED BREAKER NOT BOLTED IN, AT 100A SINGLE PHASESIEMENS PANEL |
RSLV |
10/23/2023 |
10/23/2023 |
11/14/2023 |
| |
| 002 |
(176) |
INSTALLATION DOES NOT MEET CODE REQUIREMENTS (FLOOR: 011)406.5 FACEPLATE/FINISH PLATE NOT PROVIDED FOR 120V RECEPTACLE BEHINDSTOVE |
RSLV |
10/23/2023 |
10/23/2023 |
11/16/2023 |
| |
| 003 |
(176) |
INSTALLATION DOES NOT MEET CODE REQUIREMENTS (FLOOR: 011)300.4 INSULATED FITTING NOT PROVIDED FOR #2AWG ENTERING PANEL ANDSPLICE BOX |
RSLV |
10/23/2023 |
10/23/2023 |
11/14/2023 |
| |
| 004 |
(176) |
INSTALLATION DOES NOT MEET CODE REQUIREMENTS (FLOOR: 011)250.148 EQUIPMENT GROUNDING CONDUCTOR NOT BONDED TO ENCLOSURE INSPLICE BOX WITH MAIN FEEDER |
RSLV |
10/23/2023 |
10/23/2023 |
11/14/2023 |
| |
| 005 |
( 33) |
KNOCKOUTS ARE NOT CLOSED IN OUTLET BOX (FLOOR: 011)110.12 1/2" KNOCKOUT OPEN IN TOP OF ELECTRICAL PANEL AND TOP OFSPLICE BOX WITH MAIN FEEDER, KO SEALS NOT PROVIDED |
RSLV |
10/23/2023 |
10/23/2023 |
11/14/2023 |
| |
| 006 |
( 53) |
GFCI HAS NOT BEEN PROVIDED (FLOOR: 011)210.8 GFCI PROTECTION NOT PROVIDED FOR RECEPTACLE IN MEDICINECABINET IN MASTER BATHROOM |
RSLV |
10/23/2023 |
10/23/2023 |
11/14/2023 |
| |
| 007 |
( 59) |
AFCI PROTECTION HAS NOT BEEN PROVIDED (FLOOR: 011)210.12 AFCI PROTECTION NOT PROVIDED FOR OUTLETS IN HALLWAY |
RSLV |
10/23/2023 |
10/23/2023 |
11/14/2023 |