Premises: 2681 BROADWAY MANHATTAN BIN: 1056558     Block: 1874   Lot: 7501
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 235 W 102ND ST Census Tract:   191 Health Area:  3110
APT 11F Admin Area:   Z - UPPER MANHATTAN Inspection Area:   D
NEW YORK, NY 10025 Community Board:   107
DOB Cross Street(s):   BROADWAY,    WEST END AVENUE
Status:   C - JOB IS SIGNED OFF 11/16/2023
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  05/22/2017 12:41 PM
Application Entered:   05/22/2017 Job Start Date:   05/22/2017
Last Change:   11/16/2023 Job End Date:   12/22/2017
Appointment Status:   
Last Inspection By:   SOLAVNTO, THOMAS       On     11/16/2023      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 010813 Licensee Name: RICHARD ESPOSITO
Firm: 002078 Firm Name: ALL WAYS ELECTRIC CORP.W
Firm Phone: 800-924-9297  Firm Address: 112 WEST 34TH STREET FLR 17 NEWYORK NY 10120 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $106.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: MR. STAHL
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  1  100 AMP 1 PHASE MAIN LUG
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
011  33  40  18  30             
Buildings Total 33  40  18  30                
Total Units : 124 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 10/24/2023
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  N/A

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Z160814
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 10/23/2023 10/24/2023 MJK V (66) (7)
INSPECTION COMMENTS: FAIL. INSPECTION COMPLETE. OBJECTIONS ISSUED. ATOI JOE
 
(2) 11/14/2023 11/14/2023 EID J Y (0) (0)
INSPECTION COMMENTS: CERTIFIED - OBJ-23-000046006
 
(3) 11/14/2023 11/14/2023 EID J Y (0) (0)
INSPECTION COMMENTS: CERTIFIED - OBJ-23-000046010
 
(4) 11/14/2023 11/14/2023 EID J Y (0) (0)
INSPECTION COMMENTS: CERTIFIED - OBJ-23-000046011
 
(5) 11/14/2023 11/14/2023 EID J Y (0) (0)
INSPECTION COMMENTS: CERTIFIED - OBJ-23-000046012
 
(6) 11/14/2023 11/14/2023 EID J Y (0) (0)
INSPECTION COMMENTS: CERTIFIED - OBJ-23-000046015
 
(7) 11/14/2023 11/14/2023 EID J Y (0) (0)
INSPECTION COMMENTS: CERTIFIED - OBJ-23-000046016
 
(8) 11/16/2023 11/16/2023 TSO C R (0) (0)
INSPECTION COMMENTS: CERTIFIED - OBJ-23-000047267

OBJECTION FOR APPLICATION #: Z160814
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (176) INSTALLATION DOES NOT MEET CODE REQUIREMENTS
(FLOOR: 011)408.36 100A BACKFED BREAKER NOT BOLTED IN, AT 100A SINGLE PHASESIEMENS PANEL
RSLV 10/23/2023 10/23/2023 11/14/2023
 
002 (176) INSTALLATION DOES NOT MEET CODE REQUIREMENTS
(FLOOR: 011)406.5 FACEPLATE/FINISH PLATE NOT PROVIDED FOR 120V RECEPTACLE BEHINDSTOVE
RSLV 10/23/2023 10/23/2023 11/16/2023
 
003 (176) INSTALLATION DOES NOT MEET CODE REQUIREMENTS
(FLOOR: 011)300.4 INSULATED FITTING NOT PROVIDED FOR #2AWG ENTERING PANEL ANDSPLICE BOX
RSLV 10/23/2023 10/23/2023 11/14/2023
 
004 (176) INSTALLATION DOES NOT MEET CODE REQUIREMENTS
(FLOOR: 011)250.148 EQUIPMENT GROUNDING CONDUCTOR NOT BONDED TO ENCLOSURE INSPLICE BOX WITH MAIN FEEDER
RSLV 10/23/2023 10/23/2023 11/14/2023
 
005 ( 33) KNOCKOUTS ARE NOT CLOSED IN OUTLET BOX
(FLOOR: 011)110.12 1/2" KNOCKOUT OPEN IN TOP OF ELECTRICAL PANEL AND TOP OFSPLICE BOX WITH MAIN FEEDER, KO SEALS NOT PROVIDED
RSLV 10/23/2023 10/23/2023 11/14/2023
 
006 ( 53) GFCI HAS NOT BEEN PROVIDED
(FLOOR: 011)210.8 GFCI PROTECTION NOT PROVIDED FOR RECEPTACLE IN MEDICINECABINET IN MASTER BATHROOM
RSLV 10/23/2023 10/23/2023 11/14/2023
 
007 ( 59) AFCI PROTECTION HAS NOT BEEN PROVIDED
(FLOOR: 011)210.12 AFCI PROTECTION NOT PROVIDED FOR OUTLETS IN HALLWAY
RSLV 10/23/2023 10/23/2023 11/14/2023