BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: Z158141
Premises: 196 WEST 70 STREET MANHATTAN BIN: 1076231     Block: 1141   Lot: 7502
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 2025 BROADWAY Census Tract:   153 Health Area:  4000
11J Admin Area:   Z - UPPER MANHATTAN Inspection Area:   E
NEW YORK, NY 10023 Community Board:   107
DOB Cross Street(s):   WEST 69 STREET,    WEST 70 STREET
Status:   C - JOB IS SIGNED OFF 07/22/2017
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  11/28/2016 3:38 PM
Application Entered:   11/28/2016 Job Start Date:   11/29/2016
Last Change:   07/22/2017 Job End Date:   05/29/2017
Appointment Status:   
Last Inspection By:   JOHN LAUNONEN       On     07/20/2017      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 009791 Licensee Name: JOSEPH B JORDAN
Firm: 004329 Firm Name: GOTHAM WIRING LICENSED
Firm Phone: 718-295-6430  Firm Address: 649A EAST 183RD STREET ELECTRICAL CONTRACTORS IN BRONX NY 10458 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $61.75
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: RAFAEL PARRA
Owner Business Name: MYHOME
Authorized Representative:  JOSEPH JORDAN
Relationship To Owner:   CONTRACTOR


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  1  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
011                       
011  11J  16                 
Buildings Total 16                  
Total Units : 37 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 06/07/2017
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Z158141
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 03/16/2017 03/30/2017 ADM N (55) (0) Y
INSPECTION COMMENTS: CONTRACTOR WAS A NO SHOW.
 
(2) 04/05/2017 04/06/2017 JUU V (45) (3)
INSPECTION COMMENTS: CONTRACTOR COULD NOT LOCATE NEW SPLICE FROM NEW PANEL ( 1/2" GREENFIELD ) FULL RE-INSPECTION NEEDED
 
(3) 05/16/2017 05/17/2017 BUR V X (35) (1)
INSPECTION COMMENTS: ELECTRICIAN DOES NOT KNOW SCOPE OF WORK
 
(4) 06/07/2017 06/07/2017 UMS V Y (30) (1)
INSPECTION COMMENTS: SEE OBJECTIONS
 
(5) 07/20/2017 07/20/2017 JUU C R (40) (0)
INSPECTION COMMENTS: OBJECTIONS REMOVED, OK

OBJECTION FOR APPLICATION #: Z158141
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 19) DEFECTIVE WIRING IS IN USE
(FLOOR: 011) MISSING GROUND FROM NEW PANEL IN 1/2" GREENFEILD
RSLV 04/05/2017 04/05/2017 06/07/2017
 
002 ( 19) DEFECTIVE WIRING IS IN USE
(FLOOR: 011) NEUTRAL SWITCHED IN CLOSET FOR STEAMER IN BATHROOM
RSLV 04/05/2017 04/05/2017 06/07/2017
 
003 ( 19) DEFECTIVE WIRING IS IN USE
(FLOOR: 011) BOXES SET BACK TO FAR THROUGHOUT NEED BOX EXTENDERS
RSLV 04/05/2017 04/05/2017 07/20/2017
 
004 (999) OTHER
(FLOOR: 005) RISER JCT BOX COVER NOT BONDED 300.10, 250
RSLV 05/16/2017 05/16/2017 07/20/2017
 
005 (999) OTHER
(FLOOR: 011)AFCI CIRCUIT BREAKER NOT OF COMBINATION TYPE. NEC 210.12
RSLV 06/07/2017 06/07/2017 07/20/2017



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Inspection Work Order