Electrical Application Details for App #: Z155812
Premises: 196 WEST 70 STREET MANHATTAN BIN: 1076231     Block: 1141   Lot: 7502
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 2025 BROADWAY Census Tract:   153 Health Area:  4000
27HJ Admin Area:   Z - UPPER MANHATTAN Inspection Area:   E
NEW YORK, NY 10023 Community Board:   107
DOB Cross Street(s):   WEST 69 STREET,    WEST 70 STREET
Status:   C - JOB IS SIGNED OFF 04/11/2017
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  06/26/2016 2:16 PM
Application Entered:   06/26/2016 Job Start Date:   06/26/2016
Last Change:   04/11/2017 Job End Date:   06/15/2017
Appointment Status:   
Last Inspection By:   GARY MCCALLA       On     04/10/2017      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 011313 Licensee Name: ALEX SHTRAMBRAND
Firm: 002687 Firm Name: FAS ELECTRIC, INC.
Firm Phone: 718-714-1212  Firm Address: 2127 NEPTUNE AVE BROOKLYN NY 11224 

Other Licensees and Firms:
License # Licensee Name Firm # Firm Name Type
011285 FINKEL, ANATOLIY 002687 FAS ELECTRIC, INC. RESPONSIBLE REP

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $108.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: STEPHEN FRANKLIN
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  1  3 #6THHN
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  1  8/16 SINGLE PH.MLO
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
027  27HJ  42  38  39  42             
Buildings Total 42  38  39  42                
Total Units : 162 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 03/21/2017
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  ADDITIONAL WIRING

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Z155812
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 03/20/2017 03/21/2017 STP V (30) (3)
INSPECTION COMMENTS: FAIL.
 
(2) 04/10/2017 04/11/2017 GYM C R (60) (0)
INSPECTION COMMENTS: PASS

OBJECTION FOR APPLICATION #: Z155812
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
(FLOOR: 027) BATHROOM RECEPTACLE NO TR 406.11
RSLV 03/20/2017 03/20/2017 04/10/2017
 
002 (999) OTHER
(FLOOR: 027) LED RECEPTACLE KITCHEN BURIED 314.29
RSLV 03/20/2017 03/20/2017 04/10/2017
 
003 (999) OTHER
(FLOOR: 027) LED RECEPTACLE KITCHEN NO COVER 314.25
RSLV 03/20/2017 03/20/2017 04/10/2017