Electrical Application Details for App #: Z155196
Premises: 692 FT WASHINGTON AVENUE MANHATTAN BIN: 1064474     Block: 2180   Lot: 610
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 700 FORT WASHINGTON AV Census Tract:   281 Health Area:  0222
BSMT Admin Area:   Z - UPPER MANHATTAN Inspection Area:   A
NEW YORK, NY 10040 Community Board:   112
DOB Cross Street(s):   WEST 190 STREET,    CABRINI BOULEVARD
Status:   C - JOB IS SIGNED OFF 10/28/2016
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  05/19/2016 7:48 PM
Application Entered:   05/19/2016 Job Start Date:   05/20/2016
Last Change:   10/28/2016 Job End Date:   08/20/2016
Appointment Status:   
Last Inspection By:   GARY MCCALLA       On     10/28/2016      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 009791 Licensee Name: JOSEPH B JORDAN
Firm: 004329 Firm Name: GOTHAM WIRING LICENSED
Firm Phone: 718-295-6430  Firm Address: 649A EAST 183RD STREET ELECTRICAL CONTRACTORS IN BRONX NY 10458 

Removal of ECB Violation(s): 35159807N   35159808P           
Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $78.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: STEVEN KURLANDER
Owner Business Name: EMPIRE MGMT
Authorized Representative:  JOE JORDAN
Relationship To Owner:   CONTRACTOR


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  1  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  1  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
BAS  SUPER  10  20  10               
Buildings Total 10  20  10                  
Total Units : 42 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 09/27/2016
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  REMOVING TWO ECB VIOLATIONS

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Z155196
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 07/12/2016 08/04/2016 UMS V (35) (5)
INSPECTION COMMENTS: SEE OBJECTIONS
 
(2) 09/08/2016 09/09/2016 GYM H X (50) (0) Y
INSPECTION COMMENTS: CONTRACTOR NO SHOW.
 
(3) 09/27/2016 09/27/2016 GYM V Y (55) (2)
INSPECTION COMMENTS: ADD PANEL.
 
(4) 10/28/2016 10/28/2016 GYM C R (65) (0)
INSPECTION COMMENTS: ADD LIGHTS, SW'S RECEPTACLES SEE APPL. # Z157655

OBJECTION FOR APPLICATION #: Z155196
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
(BASEMENT) PANEL INSTALLED TOO HIGH. NEC 240
RSLV 07/12/2016 07/12/2016 09/27/2016
 
002 (999) OTHER
(BASEMENT)WIRING METHOD USED FOR CLOTHES CLOSETS LIGHTS NOT APPROVED. AMEND110.2
RSLV 07/12/2016 07/12/2016 10/28/2016
 
003 (999) OTHER
(BASEMENT) RECEPTACLES NOT OF TR TYPE. NEC 406.11
RSLV 07/12/2016 07/12/2016 10/28/2016
 
004 (999) OTHER
(BASEMENT)EQUIPMENT NOT GROUNDED PROPERLY. GREEN WIRE OF MC TYPE CABLE NOTCONNECTED TO EQUIPMENT GROUND. SEE BOTH ENDS. NEC 314.4 NEC 422
RSLV 07/12/2016 07/12/2016 10/28/2016
 
005 (999) OTHER
(BASEMENT)NO DEDICATED LINES PROVIDED FOR ROOM AIR CONDITIONING . AMEND 210
RSLV 07/12/2016 07/12/2016 10/28/2016
 
006 (128) NEUTRAL IS GROUNDED BEYOND LOAD SIDE OF SERVICE SWITCH
(BASEMENT) KITCHEN ELECTRIC RANGE
RSLV 09/27/2016 09/27/2016 10/28/2016
 
007 ( 56) ELECTRICAL MATERIAL USED IS NOT SUITABLE FOR THE PURPOSE INTENDED
(BASEMENT) ELECTRIC CORD PLUG CONNECTED RANGE KITCHEN.
RSLV 09/27/2016 09/27/2016 10/28/2016