| BUILDING OVERVIEW |
Are Feeders Being Installed? : No |
| (If feeders are being installed, provide a wiring diagram and calculations at the time of inspection) |
| Building Overview Work Items |
QUANTITY |
DESCRIPTION |
| SERVICE SWITCHES |
|
| A. Up to 100 AMPS |
0 |
|
| B. 101 Up to 200 AMPS |
0 |
|
| C. 201 Up to 600 AMPS |
0 |
|
| D. 601 Up to 1200 AMPS |
0 |
|
| E. Over 1200 AMPS |
0 |
|
| SER. ENT. & FDR COND (EACH SET) |
|
| A. Up to #2 CONDUCTOR |
0 |
|
| B. Over #2 to 1/0 |
0 |
|
| C. Over 1/0 to 250 MCM |
0 |
|
| D. Over 250 MCM |
0 |
|
| PANELS |
|
| A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs |
1 |
12 CIRCUIT 1 PHASE |
| B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs |
0 |
|
| C. 3 Phase Up to 225 AMPS |
0 |
|
| D. 3 Phase Over 225 AMPS |
0 |
|
| ELEVATORS / ESCALATORS / MATERIAL LIFTS |
|
| A. Total No. of Elevators / Escalators / Material Lifts |
0 |
|
| B. Each Additional 10 Floors Or Less |
0 |
|
| BOILER CONTROLS |
0 |
|
| OBJECTION ID |
OBJECTION CODE |
OBJECTION DESCRIPTION & COMMENTS |
STAT |
FIRST |
LATEST |
RESLVD |
| |
| 001 |
(999) |
OTHER (FLOOR: 003)NO INDIVIDUAL BRANCH CIRCUIT PROVED AIR CONDITION 210.11 |
RSLV |
08/10/2017 |
08/10/2017 |
02/02/2018 |
| |
| 002 |
(999) |
OTHER (FLOOR: 003) OUTLET BOXES NOT ALL BONDED 250.146 |
RSLV |
08/10/2017 |
08/10/2017 |
02/02/2018 |
| |
| 003 |
(999) |
OTHER (FLOOR: 003) OUTLET BURIED BEDROOMS WALL 314.29 |
RSLV |
08/10/2017 |
08/10/2017 |
02/02/2018 |
| |
| 004 |
(999) |
OTHER (FLOOR: 003) BEDROOMS FIXTURES DEFECTIVE 110.2 |
RSLV |
08/10/2017 |
08/10/2017 |
02/02/2018 |
| |
| 005 |
(999) |
OTHER (FLOOR: 003) KITCHEN RECEPTACLES DEFECTIVE 110.2 |
RSLV |
08/10/2017 |
08/10/2017 |
02/02/2018 |
| |
| 006 |
(999) |
OTHER (FLOOR: 003) AFCI COMBINATION TYPE REQ 210.12 |
RSLV |
08/10/2017 |
08/10/2017 |
02/22/2018 |
| |
| 007 |
(999) |
OTHER (FLOOR: 003) DEDICATED 20 AMP. CIRCUIT TO EACH BATH ROOM 210.11 |
RSLV |
08/10/2017 |
08/10/2017 |
02/02/2018 |
| |
| 008 |
(999) |
OTHER (FLOOR: 003) MULTI WIRES HANDLE TIE 210.4 |
RSLV |
08/10/2017 |
08/10/2017 |
02/22/2018 |
| |
| 009 |
(999) |
OTHER (FLOOR: 003) BREAKERS NOT LISTED FOR PANEL 110.3(B) |
RSLV |
02/02/2018 |
02/02/2018 |
02/12/2018 |
| |
| 010 |
(999) |
OTHER (FLOOR: 003) WALL SPACE IN LIVING ROOM MISSING RECEPTACLE 210.52(A) |
RSLV |
02/02/2018 |
02/02/2018 |
02/22/2018 |
| |
| 011 |
(999) |
OTHER (FLOOR: 003)NEED 2 DEDICATED BRANCH CIRCUITS IN KITCHEN COUNTERTOP 210.52(C) |
RSLV |
02/02/2018 |
02/02/2018 |
02/12/2018 |
| |
| 012 |
(999) |
OTHER (FLOOR: 003) NEED BOX EXTENDERS IN EVERY RECEPTACLE |
RSLV |
02/02/2018 |
02/02/2018 |
02/22/2018 |
| |
| 013 |
(999) |
OTHER (FLOOR: 003) NEEDS GROUPING 210.4(D) |
RSLV |
02/02/2018 |
02/02/2018 |
02/12/2018 |
| |
| 014 |
(999) |
OTHER (FLOOR: 003) MISSING AFCI FOR LIGHTING AND SMOKE DETECTORS 210.12 |
RSLV |
02/02/2018 |
02/02/2018 |
02/12/2018 |
| |
| 015 |
(999) |
OTHER (FLOOR: 003) ELECTRIC STOVE MISSING GROUNDING 250.140 |
RSLV |
02/02/2018 |
02/02/2018 |
02/12/2018 |