BIS Menu  |  Property Profile  |  Electrical Applications  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: Z154107
Premises: 315 WEST 70 STREET MANHATTAN BIN: 1030930     Block: 1182   Lot: 20
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 315 W 70 ST Census Tract:   159 Health Area:  3900
APT 16J Admin Area:   Z - UPPER MANHATTAN Inspection Area:   E
NEW YORK, NY 10023 Community Board:   107
DOB Cross Street(s):   WEST END AVENUE,    FREEDOM PLACE
Status:   C - JOB IS SIGNED OFF 05/10/2017
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  03/16/2016 10:37 AM
Application Entered:   03/16/2016 Job Start Date:   03/16/2016
Last Change:   05/10/2017 Job End Date:   03/16/2017
Appointment Status:   
Last Inspection By:   URIM SYLA       On     03/27/2017      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 012593 Licensee Name: FARID J MARJI
Firm: 004424 Firm Name: NEW YORK EMPIRE ELECL CON
Firm Phone: 718-619-8181  Firm Address: 1236 JEROME AVENUE SERVICES INC BRONX NY 10452 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $114.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: SCOTT BELSLEY
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  1  100-AMP PANEL
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
016  16J  52  30  69             
Buildings Total 52  30  69                
Total Units : 156 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 12/05/2016
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Z154107
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 12/01/2016 12/05/2016 GYM V (40) (4)
INSPECTION COMMENTS: NOT A FINAL INSPECTION.
 
(2) 03/27/2017 03/27/2017 UMS C R (40) (0)
INSPECTION COMMENTS: OBJECTIONS REMOVED. A/C COMING FROM BUILDING A/C SYSTEM. NO DEDICATED A/C LINES NEEDED

OBJECTION FOR APPLICATION #: Z154107
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
(FLOOR: 016) AFCI MUST PROTECT ENTIRE BRANCH CIRCUITS 210.12
RSLV 12/01/2016 12/01/2016 03/27/2017
 
002 (999) OTHER
(FLOOR: 016) NEW PANEL NEUTRAL BOND NOT REQ'D 250.24
RSLV 12/01/2016 12/01/2016 03/27/2017
 
003 (999) OTHER
(FLOOR: 016) WALL COUNTERTOP RECEPTACLES 210.52
RSLV 12/01/2016 12/01/2016 03/27/2017
 
004 (999) OTHER
(FLOOR: 016)INDIVIDUAL BRANCH CIRCUIT SHALL BE PROVIDED FOR EACH AIRCONDITIONING 210.11
RSLV 12/01/2016 12/01/2016 03/27/2017