Electrical Application Details for App #: Z153569
Premises: 115 CENTRAL PARK WEST MANHATTAN BIN: 1028618     Block: 1124   Lot: 27
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 115 CENTRAL PARK W Census Tract:   157 Health Area:  4000
29/30TH Admin Area:   Z - UPPER MANHATTAN Inspection Area:   E
NEW YORK, NY 10023 Community Board:   107
DOB Cross Street(s):   WEST 71 STREET,    CENTRAL PARK EXIT WEST 72 ST
Status:   C - JOB IS SIGNED OFF 04/15/2016
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  02/10/2016 11:10 AM
Application Entered:   02/10/2016 Job Start Date:   02/10/2016
Last Change:   04/15/2016 Job End Date:   09/20/2016
Appointment Status:   
Last Inspection By:   HUGH MCKESSEY       On     04/11/2016      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 012397 Licensee Name: BRIAN W FLANAGAN
Firm: 004189 Firm Name: ECO ELECTRICAL SERVCS LLC
Firm Phone: 212-915-0610  Firm Address: 1261 BROADWAY, SUITE 504 NEW YORK NY 10001 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
7 - HVAC WIRING
Total Fee:  $1,191.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: DAVID SOLOMON
Owner Business Name: SOLOMON LLC
Authorized Representative:  PAUL CONNELL
Relationship To Owner:   EC


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  1  200 AMPS
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  5  #6 AWG
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  7  4-#3/0AWG
D. Over 250 MCM  0  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  9  8 X 4 - #2AWG & 1 X 4 -
B. Over #2 to 1/0  1  60 AMPS
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  5  60 AMPS
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  6  200 AMPS
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
029      125                   
029  C/D  13    125  34  154  14  36     
030      133        14         
030  C/D  20    133  36  189  15  36     
Buildings Total 33  258  258  70  343     16     72      
Total Units : 1050 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 2 #10-Wire 0
Existing Meters 2 + New Meters 2 - Removed Meters 2 = Total Meters 2

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 02/10/2016 Notice: 1 - FIRST NOTICE 03/24/2016
Power Issued: 02/10/2016 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Z153569
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 02/22/2016 02/23/2016 NRS J (121) (0) Y
INSPECTION COMMENTS: SEE PREVIOUS INSPECTION COMMENTS. CONTRACTOR RE-FILED FOR ORIGINAL APP.#Z138373 WITH EXISTING OBJECTIONS. SCHEDULE BOTH APP. FOR NEXT INSPECTION. SOME LIGHT FIXTURES REMOVED, BOXES ARE BLANK COVERED AT TIME OF INSPECTION.
 
(2) 03/23/2016 03/24/2016 NRS V (90) (1)
INSPECTION COMMENTS: -
 
(3) 04/11/2016 04/11/2016 HMC C R (5) (0)
INSPECTION COMMENTS: JOB OK

OBJECTION FOR APPLICATION #: Z153569
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 3) APPLICATION FOR CERTIFICATE OF ELECTRICAL INSPECTION NOT ON FILE
(FLOOR: 029) & FLOOR 30. HEATERS DO NOT SHOW ON APPLICATION
RSLV 03/23/2016 03/23/2016 04/11/2016