Electrical Application Details for App #: Z152889
Premises: 2201 BROADWAY MANHATTAN BIN: 1030903     Block: 1170   Lot: 7502
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 390 W END AV Census Tract:   167 Health Area:  3400
APT 7DS Admin Area:   Z - UPPER MANHATTAN Inspection Area:   D
NEW YORK, NY 10024 Community Board:   107
DOB Cross Street(s):   WEST 78 STREET,    WEST 79 STREET
Status:   C - JOB IS SIGNED OFF 03/08/2016
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  12/15/2015 4:53 PM
Application Entered:   12/15/2015 Job Start Date:   12/16/2015
Last Change:   03/08/2016 Job End Date:   12/01/2016
Appointment Status:   
Last Inspection By:   URIM SYLA       On     01/29/2016      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 012138 Licensee Name: IAN T BRUMGNACH
Firm: 003841 Firm Name: EASTERN ELEC'L CONST INC
Firm Phone: 718-747-3333  Firm Address: 36-38 35TH STREET LONG ISLAND.CITY NY 11106 

Work Started or Filed by Others: YES
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $92.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup:
Owner Business Name: MUNSEY ENTERPRISES
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  1  42CKTS
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
007  7DS  25  30    15               
Buildings Total 25  30    15                  
Total Units : 70 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 12/31/2015
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  THIS FILING IS TO TAKE OVER APPLICATION Z 147327

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Z152889
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 12/31/2015 12/31/2015 MQY V (166) (6)
INSPECTION COMMENTS: COULD NOT INSPECT KITCHEN LEDS IN THE PERIMETER OF THE CEILING, NO LADDER.
 
(2) 01/29/2016 02/01/2016 UMS C R (35) (0)
INSPECTION COMMENTS: ALL OBJECTIONS CLEARED

OBJECTION FOR APPLICATION #: Z152889
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
(FLOOR: 007)RECEPTACLE SET BACK ON WOOD WITHOUT PROTECTION (THROUGH OUT WOODMOLDING)(BATHROOM VANITY)(314.20)
RSLV 12/31/2015 12/31/2015 01/29/2016
 
002 (999) OTHER
(FLOOR: 007)RECEPTACLE SET BACK MORE THAN A 1/4 INCH WITHOUT PROTECTION(LOCATIONS WITH MARBLE THROUGH OUT)
RSLV 12/31/2015 12/31/2015 01/29/2016
 
003 (999) OTHER
(FLOOR: 007)AFCI PROTECTION NEEDED ON RECEPTACLES IN LAUNDRY CLOSET (210.12B)
RSLV 12/31/2015 12/31/2015 01/29/2016
 
004 (999) OTHER
(FLOOR: 007)KITCHEN ISLAND NEEDS ANOTHER RECEPTACLE ON THE OTHER SIDE OF THESINK BECAUSE THE SINK CREATES SEPARATE SPACES (210.52C4)
RSLV 12/31/2015 12/31/2015 01/29/2016
 
005 (999) OTHER
(FLOOR: 007)RISER LACKS MECHANICAL CONTINUITY WITH PANEL (BROKEN KO'S) (300.12)
RSLV 12/31/2015 12/31/2015 01/29/2016
 
006 (999) OTHER
(FLOOR: 007) LED TRANSFORMERS DRI ERS ARE NOT ACCESSIBLE (410.144)
RSLV 12/31/2015 12/31/2015 01/29/2016