BIS Menu  |  Applications  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: Z149498
Premises: 137 RIVERSIDE DRIVE MANHATTAN BIN: 1033929     Block: 1247   Lot: 57
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 137 RIVERSIDE DR Census Tract:   171 Health Area:  3400
11D Admin Area:   Z - UPPER MANHATTAN Inspection Area:   D
NEW YORK, NY 10024 Community Board:   107
DOB Cross Street(s):   WEST END AVENUE,    RIVERSIDE DRIVE
Status:   C - JOB IS SIGNED OFF 02/07/2017
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  05/07/2015 8:23 AM
Application Entered:   05/07/2015 Job Start Date:   05/07/2015
Last Change:   02/07/2017 Job End Date:   05/06/2016
Appointment Status:   
Last Inspection By:   MODELFINO, CARL C       On     02/03/2017      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 012498 Licensee Name: JAN VARJAN
Firm: 004309 Firm Name: JUMPER ELECTRIC CORP
Firm Phone: 718-775-3303  Firm Address: 4912 28TH AVENUE WOODSIDE NY 11377 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $112.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: SARA BELANICH
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  2  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
011  11D  63  80  33               
Buildings Total 63  80  33                  
Total Units : 178 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 01/19/2017
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Z149498
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 01/18/2017 01/19/2017 MQY V (40) (4)
INSPECTION COMMENTS: ISSUED OBJECTIONS
 
(2) 02/03/2017 02/06/2017 MLF C R (39) (0)
INSPECTION COMMENTS: ALL OBJECTIONS RESOLVED

OBJECTION FOR APPLICATION #: Z149498
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
(FLOOR: 011) EGC FOR HVAC SYSTEM IS UNDERSIZED @12 AWG (250.122)
RSLV 01/18/2017 01/18/2017 02/03/2017
 
002 (999) OTHER
(FLOOR: 011)GFCI NEEDED ON RECEPTACLES WITHIN 6FT FROM LAUNDRY SINK (210.8)
RSLV 01/18/2017 01/18/2017 02/03/2017
 
003 (999) OTHER
(FLOOR: 011)KITCHEN PLUG MOLD NOT PROPERLY GROUNDED (KO HOLE IS TO BIG FOR THEBX CONNECTOR (250.148)
RSLV 01/18/2017 01/18/2017 02/03/2017
 
004 (999) OTHER
(FLOOR: 011) WHITE WIRE USED AS A UNGROUNDED CONDUCTOR (200.7)
RSLV 01/18/2017 01/18/2017 02/03/2017



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Applications  |  Electrical Inspection Work Order  |  Back