BIS Menu  |  Elevators  |  Electrical Applications  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: Z148990
Premises: 351 WEST 45 STREET MANHATTAN BIN: 1025006     Block: 1036   Lot: 5
   

DOB NOW: Inspections


Filed: 351 W 45 ST Census Tract:   121 Health Area:  4500
BASEMENT, 12 APARTMENTS Admin Area:   Z - UPPER MANHATTAN Inspection Area:   G
NEW YORK, NY 10036 Community Board:   104
DOB Cross Street(s):    8 AVENUE,    9 AVENUE
Status:   K - CLOSED/CANCELLED 02/02/2017
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  04/07/2015 9:32 PM
Application Entered:   04/07/2015 Job Start Date:   04/07/2015
Last Change:   02/02/2017 Job End Date:   09/15/2015
               COMPLETION FEE WAS BILLED
Appointment Status:   
Last Inspection By:   SCHULER, THOMAS       On     02/01/2017      
Field Disp:   K - OK TO CANCEL
Energize Recommendation:  
Objection Disposition:  

License #: 012152 Licensee Name: EDIN BECIROVIC
Firm: 003854 Firm Name: NEW KC ELECTRIC INC
Firm Phone: 718-392-0077  Firm Address: 36-32 23 STREET LONG ISLAND CITY NY 11106 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $1,133.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: ANDREW WRUBLIN
Owner Business Name: DALAN MANAGEMENT
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  1  600A
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  22  APARTMENT FEEDERS
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  2  2 SETS POF 350MCM
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  22  20 SPACE
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  1  PLP
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
001  CE  17             
001  CW  16             
002  1FE  17             
002  1FW  16             
003  2FE  17             
003  2FW  16             
004  3FE  17             
004  3FW  16             
005  4FE  17             
005  4FW  16             
006  5FE  17             
006  5FW  16             
Buildings Total 108  198  24  84  108                
Total Units : 522 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 22 #4-Wire 1 #10-Wire 0
Existing Meters 23 + New Meters 23 - Removed Meters 23 = Total Meters 23

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 04/07/2015 Notice:  
Power Issued: 04/07/2015 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  REWIRING 12 APARTMENTS, REPLACING METERING EQUIPMANT

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Z148990
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 02/01/2017 02/02/2017 TUR K (60) (0) Y
INSPECTION COMMENTS: CONTRACTOR DID NOT DO ANY WORK IN ANY APARTMENTS THE ONES LISTED ARE GUTTED AND BASEMENT SERVICE IS EXISTING




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Elevators  |  Electrical Applications  |  Electrical Inspection Work Order  |  Back