Electrical Application Details for App #: Z148660
Premises: 37 WEST 97 STREET MANHATTAN BIN: 1074358     Block: 1833   Lot: 7501
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 382 CENTRAL PARK W Census Tract:   185 Health Area:  3210
APT. 9C Admin Area:   Z - UPPER MANHATTAN Inspection Area:   D
NEW YORK, NY 10025 Community Board:   107
DOB Cross Street(s):    97 ST TRANSVERSE,    COLUMBUS AVENUE
Status:   C - JOB IS SIGNED OFF 01/15/2016
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  03/19/2015 3:24 PM
Application Entered:   03/19/2015 Job Start Date:   03/19/2015
Last Change:   01/15/2016 Job End Date:   03/19/2016
Appointment Status:   
Last Inspection By:   MICHAEL QUERY       On     01/04/2016      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 011372 Licensee Name: STEVEN DENNISON
Firm: 003326 Firm Name: DENNISON ELECTRIC CORP
Firm Phone: 718-803-6421  Firm Address: 37-31 58TH STREET WOODSIDE NY 11377 

Work Started or Filed by Others: YES
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $70.75
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: TIM / CAROL STEVENSON
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  1  100 AMPS 220 VOLTS
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
009  9C    30    15  25         
Buildings Total   30    15  25              
Total Units : 73 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 12/29/2015
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  INSTALL LIGHTS, SWITCHES, RECPS, CIRCUIT BRAKER PANEL,1 CONDENSER AND 3 WALL MOUNTED FAN FOR A/C UNIT FOR APT 9C

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Z148660
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 12/09/2015 12/11/2015 MQY V (92) (4)
INSPECTION COMMENTS: INSPECTION COMPLETED OBJECTIONS ISSUED
 
(2) 12/29/2015 12/29/2015 MQY V Y (70) (1)
INSPECTION COMMENTS: LED TRANSFORMERS NOT ACCESSIBLE AFTER INSTALLATION (NEC ARTICLE 410.144)
 
(3) 01/04/2016 01/05/2016 MQY C R (22) (0)
INSPECTION COMMENTS: CONTRACTOR CUT LOAD SIDE OF KITCHEN, BATHROOM CABINET LIGHT, IN THE SWITCH BOX. LIGHTS &DRIVER NO LONGER IN USE.

OBJECTION FOR APPLICATION #: Z148660
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
(FLOOR: 009)LED DRIVERS INSTALLED IN THE KITCHEN ARE NOT SUPPORTED THEY ARESIMPLY JUSR RESTING ON THE INSIDE PART OF THE WOOD CABINETSTHEREFORE WILL SUBJECT THE CABINETS TO HEAT (410.144 C)
RSLV 12/09/2015 12/09/2015 01/04/2016
 
002 (999) OTHER
(FLOOR: 009)RECEPTACLES SET BACK MORE THAN A 1/4 INCH WITHOUT PROTECTION(314.20) NEXT TO WINDOWS ON TOP OF RADIATOR
RSLV 12/09/2015 12/09/2015 12/29/2015
 
003 (999) OTHER
(FLOOR: 009) DINING ROOM NEEDS TO BE ARC FAULT PROTECTED(210.12)
RSLV 12/09/2015 12/09/2015 12/29/2015
 
004 (999) OTHER
(FLOOR: 009)LED DRIVERS IN THE KITCHEN AND BATHROOM ARE NOT ACCESSIBLE.(410.144 A)
RSLV 12/09/2015 12/09/2015 01/04/2016
 
005 (999) OTHER
(FLOOR: 009)LED DRIVERS NOT ACCESSIBLE AFTER INSTALLATION (KITCHEN&BATHROOM)(410.144)
RSLV 12/29/2015 12/29/2015 01/04/2016