BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: Z147648
Premises: 80 CENTRAL PARK WEST MANHATTAN BIN: 1028458     Block: 1121   Lot: 29
  Printable (PDF) version of this Permit  

DOB NOW: Inspections


Filed: 80 CENTRAL PARK W Census Tract:   153 Health Area:  4000
APARTMENT 18A Admin Area:   Z - UPPER MANHATTAN Inspection Area:   E
NEW YORK, NY 10023 Community Board:   107
DOB Cross Street(s):   WEST 68 STREET,    WEST 69 STREET
Status:   P - OBJECTN PENDING AT CONTRACTOR 02/23/2016
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  01/06/2015 1:23 PM
Application Entered:   01/06/2015 Job Start Date:   01/07/2015
Last Change:   02/23/2016 Job End Date:   01/01/2016
               COMPLETION FEE WAS BILLED
Appointment Status:   
Last Inspection By:   URIM SYLA       On     02/22/2016      
Field Disp:   G - CANCELLATION DENIED
Energize Recommendation:  
Objection Disposition:  X - NOT REMOVED

License #: 009745 Licensee Name: LOUIS DEMICHELE
Firm: 002678 Firm Name: ALL AROUND ELECTRIC CORP.
Firm Phone: 718-686-2710  Firm Address: 5403 4TH AVENUE BROOKLYN NY 11220 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $48.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: ANNE CRONIN
Owner Business Name: NA
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
018  20      20             
Buildings Total 20      20                
Total Units : 44 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag: V - OBJECTION(S) EXIST
Power Requested: Notice: C - CALL TO OFFICE 02/23/2016
Power Issued: Response:  

Follow-Up:
Contractor's Comments:  NO NEW BRANCH CIRCUIT, REPLACEMENTS ONLY.

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Z147648
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 05/15/2015 05/22/2015 EDB A (45) (3) Y
INSPECTION COMMENTS: NONE
 
(2) 02/22/2016 02/23/2016 UMS G X (60) (0) Y
INSPECTION COMMENTS: NO ACCESS TO APT

OBJECTION FOR APPLICATION #: Z147648
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 53) GFCI HAS NOT BEEN PROVIDED
T-OUT: 6' FROM SINK, BALCONY; NO GFCI PROTECTION 210.8
OPEN 05/15/2015 05/15/2015
 
002 ( 29) OUTLET BOXES ARE NOT COVERED
KITCHEN: OUTLET BOX: MISSING COVERED 314.25
OPEN 05/15/2015 05/15/2015
 
003 (340) RECEPTACLES NOT TAMPERPROOF
KITCHEN: TAMPER PROOT RECEOTACLE NOT PROVIDED 406.11
OPEN 05/15/2015 05/15/2015



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.