BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: Z142514
Premises: 230 WEST 113 STREET MANHATTAN BIN: 1055122     Block: 1828   Lot: 42
   

Filed: 230 W 113 ST Census Tract:   216 Health Area:  2400
LOBBY & BASEMENT Admin Area:   Z - UPPER MANHATTAN Inspection Area:   C
NEW YORK, NY 10026 Community Board:   110
DOB Cross Street(s):   ADAM CLAYTON POWELL JR BOULEVARD,    FREDERICK DOUGLASS BOULEVARD
Status:   C - SIGNOFF IS AWAITING FEE PAYMENT 03/11/2015
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  12/27/2013 11:58 AM
Application Entered:   12/27/2013 Job Start Date:   12/27/2013
Last Change:   03/11/2015 Job End Date:   11/20/2014
Appointment Status:   
Last Inspection By:   GARY MCCALLA       On     03/04/2015      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 009252 Licensee Name: MORRIS HELLER
Firm: 000647 Firm Name: HELLER ELECTRIC CO., INC.
Firm Phone: 718-871-0800  Firm Address: 620 CONEY ISLAND AVE BROOKLYN NY 11218 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $133.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: D S
Owner Business Name: SIMON DEVELOPMENT GROUP,
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  2  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  2  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
BAS    42  41  27  11             
LOB    10               
Buildings Total 52  41  27  13              
Total Units : 142 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 2 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 12/27/2013 Notice: 1 - FIRST NOTICE 01/26/2015
Power Issued: 12/27/2013 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Z142514
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 01/20/2015 01/26/2015 GYM A E (50) (4) Y
INSPECTION COMMENTS: NONE
 
(2) 03/04/2015 03/11/2015 GYM C R E (65) (0) Y
INSPECTION COMMENTS: NONE

OBJECTION FOR APPLICATION #: Z142514
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
BASEMENT LIVING ROOM OUTLET FOR AIR CONDITIONER MISSING ART. 210.52
RSLV 01/20/2015 01/20/2015 03/04/2015
 
002 ( 29) OUTLET BOXES ARE NOT COVERED
BASEMENT OUTLET BOXES MISSING COVERS
RSLV 01/20/2015 01/20/2015 03/04/2015
 
003 ( 30) OUTLET BOXES ARE NOT SECURED
BASEMENT OUTLET BOXES
RSLV 01/20/2015 01/20/2015 03/04/2015
 
004 ( 9) SQ AREA OF SUM OF CONDUCTORS EXCEEDS SQ AREA FILL OF RACEWAY
BASEMENT METER PAN AND DISC. SWS
RSLV 01/20/2015 01/20/2015 03/04/2015



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Inspection Work Order