Electrical Application Details for App #: Z139605
Premises: 318 WEST 86 STREET MANHATTAN BIN: 1033923     Block: 1247   Lot: 43
   
Application Completed and Certified

Filed: 320 W 86 ST Census Tract:   171 Health Area:  3400
4 A Admin Area:   Z - UPPER MANHATTAN Inspection Area:   D
NEW YORK, NY 10024 Community Board:   107
DOB Cross Street(s):   WEST END AVENUE,    RIVERSIDE DRIVE
Status:   C - JOB IS SIGNED OFF 09/19/2014
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  05/19/2013 10:01 PM
Application Entered:   05/19/2013 Job Start Date:   05/19/2013
Last Change:   09/19/2014 Job End Date:   05/01/2014
Appointment Status:   
Last Inspection By:   MCPARTLAND, BRIAN       On     08/29/2014      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 011440 Licensee Name: MARIO F CASTRO
Firm: 004009 Firm Name: POWER SURGE ELECTRIC, INC
Firm Phone: 718-276-9797  Firm Address: 122-20 MONTAUK STREET SPRINGFIELD GARDENS NY 11413 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $104.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: DAVID L WEIL
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  1  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
004  4A  40  30  15  30             
Buildings Total 40  30  15  30                
Total Units : 118 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 1 #4-Wire 0 #10-Wire 0
Existing Meters 30 + New Meters 1 - Removed Meters 1 = Total Meters 30

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 05/19/2013 Notice: 1 - FIRST NOTICE 07/30/2014
Power Issued: 05/19/2013 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Z139605
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 07/25/2014 07/30/2014 PHG V E (40) (12) Y
INSPECTION COMMENTS: A/C IN BED ROOM AND KITCHEN
 
(2) 08/29/2014 09/04/2014 BMP C R E (40) (0) Y
INSPECTION COMMENTS: NONE

OBJECTION FOR APPLICATION #: Z139605
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 22) FIXED EQUIPMENT IS NOT PROPERLY GROUNDED
4A NO GRND FOR FEED LINE CHANGE TO FME 250.112
RSLV 07/25/2014 07/25/2014 08/29/2014
 
002 ( 59) AFCI PROTECTION HAS NOT BEEN PROVIDED
4A NO AFCI PROVIDED FOR BABY ROOM 210.12
RSLV 07/25/2014 07/25/2014 08/29/2014
 
003 ( 59) AFCI PROTECTION HAS NOT BEEN PROVIDED
4A NO AFCI FOR 120V CKT IN LAUNDRY CLOSET 210.12
RSLV 07/25/2014 07/25/2014 08/29/2014
 
004 ( 30) OUTLET BOXES ARE NOT SECURED
4A ALL A/C BOXES NOT SUPPORTED 314.23
RSLV 07/25/2014 07/25/2014 08/29/2014
 
005 ( 59) AFCI PROTECTION HAS NOT BEEN PROVIDED
4A NO AFCI FOR ALL 110V A/C CKTS 210.12
RSLV 07/25/2014 07/25/2014 08/29/2014
 
006 ( 22) FIXED EQUIPMENT IS NOT PROPERLY GROUNDED
4A ALL BOXES WITH M/C CABLE NOT BONDED 250.112
RSLV 07/25/2014 07/25/2014 08/29/2014
 
007 (999) OTHER
4A LIVING ROOM LIGHT FIXTURE NEEDS APPROVAL 110.2
RSLV 07/25/2014 07/25/2014 08/29/2014
 
008 ( 22) FIXED EQUIPMENT IS NOT PROPERLY GROUNDED
4A XFMR LED LIGHTS NOT GRND 250.112
RSLV 07/25/2014 07/25/2014 08/29/2014
 
009 ( 53) GFCI HAS NOT BEEN PROVIDED
4A BATH ROOM HEATER NOT GFCI PROTECTED 210.8
RSLV 07/25/2014 07/25/2014 08/29/2014
 
010 (999) OTHER
4A NO FIRE STOP IN FREIGHT HALL 300.21
RSLV 07/25/2014 07/25/2014 08/29/2014
 
011 (999) OTHER
4A BURRIED BOXES IN BED ROOM AND KITCHEN A/C 314.29
RSLV 07/25/2014 07/25/2014 08/29/2014
 
012 ( 29) OUTLET BOXES ARE NOT COVERED
4A A/C RECEPTICLES NO FINISH PLATE 314.25
RSLV 07/25/2014 07/25/2014 08/29/2014