Electrical Application Details for App #: Z139456
Premises: 564 WEST 188 STREET MANHATTAN BIN: 1063808     Block: 2158   Lot: 7
   
Application Completed and Certified

Filed: 564 W 188 ST Census Tract:   269 Health Area:  0210
564W 188TH STREET Admin Area:   Z - UPPER MANHATTAN Inspection Area:   A
NEW YORK, NY 10040 Community Board:   112
Special Place Name:   ST. NICHOLAS AVENUE
DOB Cross Street(s):   AUDUBON AVENUE,    ST NICHOLAS AVENUE
Status:   C - JOB IS SIGNED OFF 07/17/2013
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  05/08/2013 5:38 PM
Application Entered:   05/08/2013 Job Start Date:   05/15/2013
Last Change:   07/17/2013 Job End Date:   06/17/2013
Appointment Status:   
Last Inspection By:   MCPARTLAND, BRIAN       On     06/27/2013      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  

License #: 010207 Licensee Name: VINCENT H COLE
Firm: 001547 Firm Name: WOODSIDE ELECTRIC CORP.
Firm Phone: 718-409-5607  Firm Address: 1408 SEABURY AVENUE BRONX NY 10461 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
Total Fee:  $165.25
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   Z - Commercial/Residential (1  Stores, 54 Apartments)
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: ISSUS ALVAREZ
Owner Business Name: LE HAIRCUT TALENT LTD
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  1  1-200 AMP SERVICE SWITCH.
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  1 SET 2/0 AWG
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  1  1-30 CKT 3-WIRE PANEL.
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
GND    12  30  12             
Buildings Total 12  30  12                
Total Units : 61 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 1 #4-Wire 0 #10-Wire 0
Existing Meters 53 + New Meters 1 - Removed Meters 0 = Total Meters 54

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 05/08/2013 Notice:  
Power Issued: 05/08/2013 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  SERVICE UPGRADE AND NEW BRANCH WIRING.

 
Inspection Details
 

INSPECTION FOR APPLICATION #: Z139456
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 06/27/2013 07/17/2013 BMP C E (45) (0) Y
INSPECTION COMMENTS: NONE




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.